Performance Specifications - Mitsubishi AJ65BT-R2N-U-HW User Manual

Melsec-a series, cc-link system rs-232 interface module
Table of Contents

Advertisement

2.2 Performance Specifications

Item
RS-232
Interface
Communication
method
Synchronization
method
Transmission speed
Transmission
distance
Start bit
Data bit
Data
format
Parity bit
Stop bit
Error
Parity
detection
check
Communication
control (Flow control)
OS reception area
CC-Link
CC-Link station type
Connection cable
No. of occupied
stations
No. of writes to
2
E
PROM
Withstand voltage
Insulation resistance
Noise immunity
Module fixing screw
Applicable DIN rail
External power supply
Allowable momentary
power failure time
External dimensions
Weight
Table 2.2 Performance specifications
RS-232 compliant (D-Sub 9P)
Full-duplex communication method
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600
(Select with RS-232 transmission setting switches.)
Checked (even/odd)/Not checked
CC-Link dedicated cable/CC-Link high-performance cable/CC-Link
1 station (RX/RY: 32 points each, RWw/RWr: 4 points each)
One minute at 500V AC between all external DC terminals and ground
500V DC between all external DC terminals and ground, 10M
more with insulation resistance tester
DC type noise voltage: 500Vp-p,
tested by noise simulator of noise width of 1 s and noise frequency of
M4 0.7mm 16mm or larger
DIN-rail mounting is also possible.
TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (Compliant with IEC 60715)
24V DC (20.4 to 26.4V DC, the ripple ratio is 5% or less)
Current consumption: 0.11A (TYP. 24V DC)
Specifications
-
Asynchronous method
*1
115200
(bps)
Up to 15m
1
7/8
1 (Vertical parity)/None
1/2
DTR/DSR (ER/DR) control
DC1/DC3 control
5120 bytes
-
Intelligent device station
Ver.1.10-compatible cable
Up to 100,000 times
25 to 60Hz
1ms
80(H) 170(W) 47(D) [mm]
0.40kg
3
*1
,
*2
or

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj65bt-r2n

Table of Contents