Installing a Double-Wide GPU Card
Table 18: C240 M5 Operating Temperature Requirements For GPU Cards
GPU Card
NVIDIA Tesla M10
NVIDIA Tesla P40
NVIDIA Tesla P100 12GB
NVIDIA Tesla P100 16GB
AMD FirePro S7150 X2
Note
The GPU card might be shipped with two power cables: a straight cable and a Y-cable. The straight cable
is used for connecting power to the GPU card in this server; do not use the Y-cable, which is used for
connecting the GPU card in external devices only (such as the Magma chassis).
Step 1
Shut down and remove power from the server as described in
on page
39.
Step 2
Slide the server out the front of the rack far enough so that you can remove the top cover. You might have to detach
cables from the rear panel to provide clearance.
Caution
If you cannot safely view and access the component, remove the server from the
rack.
Step 3
Remove the top cover from the server as described in
Step 4
Remove an existing GPU card:
a) Use two hands to grasp the metal bracket of the PCIe riser and lift straight up to disengage its connector from the
socket on the motherboard. Set the riser on an antistatic surface.
b) On the bottom of the riser, press down on the clip that holds the securing plate.
c) Swing open the hinged securing plate to provide access.
d) Open the hinged plastic retainer that secures the rear-panel tab of the card.
e) Disconnect the GPU card's power cable from the power connector on the PCIe riser.
f) Pull evenly on both ends of the GPU card to remove it from the socket on the PCIe riser.
Step 5
Install a new GPU card:
Observe the configuration rules for this server, as described in
Note
149.
a) Align the GPU card with the socket on the riser, and then gently push the card's edge connector into the socket. Press
evenly on both corners of the card to avoid damaging the connector.
b) Connect the GPU power cable. The straight power cable connectors are color-coded. Connect the cable's black
connector into the black connector on the GPU card and the cable's white connector into the white GPU POWER
connector on the PCIe riser.
Cisco UCS C240 M5 Server Installation and Service Guide
152
Maximum Server Operating Temperature (Air
Inlet Temperature)
35° C (95.0° F)
32° C (89.6° F)
28° C (82.4° F)
28° C (82.4° F)
35° C (95.0° F)
Shutting Down and Removing Power From the Server,
Removing the Server Top Cover, on page
GPU Card Configuration Rules, on page
GPU Card Installation
41.