Measuring System - Endress+Hauser Levelflex FMP50 Technical Information

Guided level-radar level measurement in liquids
Hide thumbs Also See for Levelflex FMP50:
Table of Contents

Advertisement

Measuring system

6
General notes on probe selection
Normally use rod probes for liquids. Rope probes are used in liquids for measuring ranges > 4 m (13 ft) and
with restricted ceiling clearance which does not allow the installation of rigid probes.
Probe selection
The various types of probe in combination with the process connections are suitable for the following
applications:
Type of probe
Feature 060 - Probe:
Option:
AA
AB
Max. probe length
For application
If required, rod and rope probes can be replaced. They are secured with a thread coating.
For further information on service and spare parts please contact the Endress+Hauser service.
Levelflex FMP50
Rod probe
Rope probe
A0011387
Option:
8 mm (316L)
LA
4 mm (316)
1/3" (316L)
LB
1/6" (316)
4 m (13 ft)
level measurement in liquids
Levelflex FMP50
A0011388
12 m (40 ft)
Endress+Hauser