= 2,9 psi
max
(0,2 bar)
max.
6,5 feet
min
6,5
feet
- Always disconnect the plugs of the Filtoclear UVC and of all devices
that are in the water before you carry out any work on the Filtoclear!
- For your own safety, contact an electrician if you have any
questions or problems regarding the electrical connection!
- Never immerse the device in water!
- Electrical installations near garden ponds and swimming pools
must comply with international and national installation
guidelines.
- Keep the connecting points dry!
- Do not carry or pull the Filtoclear by its connecting lead! Protect
the connecting lead from heat, oil and sharp edges.
- Lay the hoses and connecting lead in such a way that they are
not an obstacle and do not become damaged!
- Caution! Danger! Never operate the Filtoclear pressure filter
with integrated UVC with a water pressure greater than 2,9 psi (
0,2 bar)! The height difference between the filter lid and the
pressure-free outlet point can therefore be 6,5 feet max. The
maximum delivery pressure of the pump being used must not
exceed 7,25 psi ( 0,5 bar).
- Only operate the Filtoclear with pressure hoses that are
approved for at least 2,9 psi ( 0,2 bar), i.e. the maximum pressure
of the pump.
- Check and clean the water outlet to the pond on a regular ba-
sis. The outlet should always be clear, as any blockage would
result in the filter being operated at a pressure greater than 2,9
psi ( 0,2 bar). This in turn would lead to the risk of leaking and
therefore of the pond emptying completely.
- Important: When the Filtoclear is being used in 'filter' mode,
the cleaning connection or any drainage hose connected to it
must always be sealed with the sealing cap and inserted flat
seal in order to prevent the pond from emptying. At the same
time the sealing cap acts as a safeguard in case the function
switch is accidentally set to 'Clean'.
- Make sure that the function switch is always set to 'Filter' when
the pump is in operation. The function switch may only be set to
'Clean' when cleaning the filter sponges with the handle function.