Installation Of The Unit - EAS Electric EBP-06W/1 Owner's Manual And Installation Instructions

Swimming pool water heater
Table of Contents

Advertisement

3.1 Precautions before installation:
1)
Decide the correct way of conveying the equipment.
2)
Try to transport this equipment with the original package.
3)
If the unit needs to be installed on a metal part of the building,
electric insulation must be performed, and the installation must
meet the relevant technical standards of electric devices.
3.2 Installation space
1)
Before installing the unit, reserve the space of maintenance
shown in the following figure.
2)
Ensure enough space for installation and maintenance.(See
Fig.3-1,Fig.3-2)
3)
If the unit installed in a underground chamber, an indoor room
or other hermetic place, please pay attention to where surround-
ing air, as well as which air exhaust and air circulating system.
For every signal unit, which circulating air volume shall not less
3
than 2400m
/h.
≥200mm
Air outlet
Prohibit any blocking to the air outlet
(Wall or obstacle)
Air inlet
>300mm
N
Air inlet
M
All the pictures in this manual are for explanation purpose
only. They may be slightly different from the water heater
you purchased(depend on model).The actual shape shall
prevail.
3
≥500mm
Main unit
Fig.3-1
Maintain channel
>600mm
P
Air outlet
Fix with bolt
Fig.3-2
NOTE

4. INSTALLATION OF THE UNIT

4.1 Installation
1)
Confirm the model, serial number and name to avoid mistaken
installation.
2)
The installation must be simple and allow for easy maintenance
interventions.
3)
The appliance must be level to allow for the gravitational
evacuation of possible condensation produced during
operation. The blower must not be directed towards surrounding
windows. Vibrations and noise must not be transmitted to a
building close by.
4)
Tools required for installation :
1 set of flat head screwdrivers
1 set of crosshead screwdrivers
1 cutter
1 wire stripper
1 pipe or round head spanner 13
1 ratchet spanner
1 pliers
2 straps (for handling)
4.2 Carrying the unit onto the installing site
1)
Please put down the main unit as gentle as possible during
removing, main unit could be leaned no more than 45 degree.
2)
In order to avoid scratch or deform the unit surface, apply guard
boards to the contacting surface.
3)
After move onto installing site, please confirm the main unit is
placed in horizontal.
4)
Choose the appliance installation site according to the following
criteria:
The clearance around the appliance must be respected
(see minimum dimensions on the drawings below) to avoid
recycling of cold air produced.
5)
Do not install the heat pump close to an inflammable gas
source.
6)
Do not install the heat pump close to a road or path to protect
the appliance against mud splashing.
Avoid places that are subject to strong winds, in particular if the
7)
wind blows against the appliance's air outlet.
8)
The installation as well as electric and hydraulic connections
must be carried out in compliance with applicable standards.
9)
Keep the appliance out of reach of children.
1.5m
Dense obstacle (hedge, wall, fencing).
0.2m
0.5m
0.3m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ebp-14w/1Ebp-12w/1Ebp-08w/1

Table of Contents