8. REGULATOR OPERATION

8.1 The introduction of controller's user
access
Control Panel Explanation
The wire length of the wire controller is 1m.
After you finish operating the wire-controller, you must cover
the wire-controller's waterproof box to prevent the rain
demaging the wire-controller.
8.2 Name and function description of LCD
screen of wire controller
Display Explanation
COOL indicator: When user sets the cooling water mode, it lights up.
HEAT indicator: When user sets the heating water mode, it lights up.
PUMP indicator: When user sets the pump mode, it lights up.
POOL TEMP indicator: The outlet water temp.
SET TEMP indicator: Show the setting .erature and blank when
screen protection. Codes are show at the malfunction or protection
time
ALARM indicator: It will flashing at the malfunction or protection time
NOTE
Fig.8-1
Table 8-1
8.3 Names of keys on the wire controller
and the keypad operation description
MODE
E0
MODE key, used to set different modes
UP key, used to add time or temp.
DOWN key, used to abate time or temp.
LIGHT,
ighting: Working Light off: Standby,Light up in 0.2S,
l
and then off in 0.2S:Reparable error,Light up in 1S, and then
off in 1S: Data storage chip error
ON/OFF key, used to turn the unit on or off
8.4 Application of wire controller
1)
Preparation before running the unit.
When you run the unit for the first time, all the indicators on the
wire controller will light for 3s, and then, display the fiducial web
page. After no operation for 40s, all indicators will go out
automatically except POOL TEMP indicator lighting.
When the unit is running, if there is no operation or malfunction
for 10s, the backlight of the display will go out automatically.After
30s ,all indicator will disappear except operation mode and pool
temp.
2)
Mode Selection
The unit is enhanced with three operation modes, Cool Mode,
Heat Mode and Pump Mode.
Cool Mode: The unit cools down swiming pool water by
compressor drive according to heat-pump principle. Used when
the swiming temp. is high in summer.
Heat Mode:The unit heats swiming pool water by compressor
drive according to heat-pump principle. Used when the ambient
temp. is low.
Pump Mode:The pump run for circling the water. Used when trial
run or other necessary situation.
By default, the unit operates Heat Mode. Change:
Press the MODE key, operation mode
will be shifted among the three modes
in a cycle, mean while the correspo-
nding indicator on the display will light
up.
ON/OFF
Fig.8-2
MODE
Fig.8-3
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ebp-14w/1Ebp-12w/1Ebp-08w/1

Table of Contents