Running And Capability; Heating Operation - EAS Electric EBP-06W/1 Owner's Manual And Installation Instructions

Swimming pool water heater
Table of Contents

Advertisement

2)
Model: 6kW 8kW 12kW 14kW
T4
T3
T6
Tp
N.C.
Pro_H
Pro_L
N.C.
Pro_Hyd.O
N.C.

7. RUNNING AND CAPABILITY

7.1 About the 3-minute protection
Restart or open the manual switch after the unit has shut down.
Unit will not start immediately until 3 minutes later, because of the
self-protect function of the compressor.
7.2 Characteristics of heat pump heating
operation
During operation, if outdoor temperature is higher than normal,
the air supply motor will runs at low air volume or stop running.
7.3 About defrosting function perform at

heating operation

1)
In case of the unit requiring deicing during heating operation, TO
prevent the heating efficiency from decreasing, defrosting opera-
tion will turn on automatically (approx. 2~10 minutes) .
2)
In the process of defrosting operation, the unit air supply motor
will stop running.
3)
Reminder: During the defrost cycle a steam cloud (water vapour)
may appear from the back of the unit (after a defrost cycle, when
the fan(s) are restarted. This cloud is evacuated to the back of the
unit).
7.4 Operating conditions of the water heating
heat pump
N.C.
Tout N.C.
1)
In order to use the water heating heat pump correctly, please
ensure that operate is at -7 ~38
ture.
2)
When water inlet pressure over than 0.4MPa, a pressure relief
valve has to be mounted at the water system.
3)
A sufficient water flow must pass into the heat pump.
7.5 About protection device
When protection device does operate, though the unit stops, the
1)
operating indicator of wire control still will be blinking.
When protection device is operates, nixie indicator will display
2)
malfunction code (unit).
3)
Protection device will act when the following circumstances
occur:
Air inlet or outlet are blocked.
Air in water or refrigerant system completely exhausted.
Voltage is a little higher or lower compare to the voltage range
(Exceeding the range of 206.8~254.4V)
CAUTION
Please cut off the manual switch power when unit is faulty.
Do not restart until problems are solved.
Fig.6-3
outdoor ambient tempera-
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ebp-14w/1Ebp-12w/1Ebp-08w/1

Table of Contents