Accessories; Installation Location - EAS Electric EBP-06W/1 Owner's Manual And Installation Instructions

Swimming pool water heater
Table of Contents

Advertisement

After a long use, check the unit stand and fitting for
damage.
If damaged, the unit may fall and result in injury.
To avoid oxygen deficiency,ventilate the room sufficiently
if equipment with burner is used together with the water
heater.
Arrange the drain hose to ensure smooth drainage.
Incomplete drainage may cause wetting of the building,
furniture etc.
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch, and a machine trouble may happen.
Never expose little children, plants or animals directly to
the air flow.
Adverse influence to little children, animals and plants may
result.
The appliances connected to the water mains
The maximum inlet water pressure is 0.4MPa,when the press-
ure >0.4MPa,please add a pressure-relief valve.
Maximum outlet water temperature range
Mode
Cooling
Temperature
Model
setting range
6kW 8kW
12kW 14kW
NOTE
The maximum target temperature is limited to 35°C in order
to protect the swimming pool liner.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
That the appliance shall be installed in accordance with
national wiring regulations.
The water may drip from the discharge pipe of the pressure-
relief device and that this pipe must be left open to the
atmosphere.
The pressure-relief device is to be operated regularly to
remove lime deposits and to verify that it is not blocked.
A discharge pipe connected to the pressure-relief is to be
installed in a continuously downward direction and in a frost-
free environment.
The means for disconnection from a power supply shall be
incorporated in the fixed wiring and have an air gap contact
separation of at lease 3mm in each (phase) conductor.
Table 1-1
Heating
Temperature
Default
Default
setting range

2. ACCESSORIES

Accessory name
Qty. Shape
Installation & owner's
1
Manual
Seal ring
1
Water outlet jointing pipe
1

3. INSTALLATION LOCATION

Enough space of installation and maintenance is available.
The air inlet and outlet are free from obstacles and strong wind.
The bearing surface is level and can bear weight of the unit, and
is suitable for installing the unit without increasing noise or
vibration.
The operation noise and the expelling of air do not affect
neighbors.
No flammable gas is leaked.
It is convenient for piping and wiring.
CAUTION
Installing the equipment in any of the following places may lead to
faults of the equipment (if that is inevitable, please consult the
dealer):
The site contains mineral oils such as cutting lubricant.
Hot spring area where corrosive gases exist, e.g., sulfide gas.
Factories where the supply voltage fluctuates seriously.
Inside a car or cabin.
Place like kitchen where oil permeates.
Place where strong electromagnetic waves exist.
Place where flammable gases or materials exist.
Other special environments.
The unit must be shipped and stored in the upright position on a
pallet and in the original packaging. In the contrary
case, place the unit in the vertical position on the pallet and
check its global state.
Under no circumstances may the heat pump be operated
immediately if it was placed horizontally. Wait at least 12 hours
before operating the pump.
Table 2-1
Purpose
This
For install and use instruction
manual
Discharge condensate water
Discharge condensate water
2