EAS Electric EBP-06W/1 Owner's Manual And Installation Instructions

EAS Electric EBP-06W/1 Owner's Manual And Installation Instructions

Swimming pool water heater

Advertisement

SWIMMING
POOL
INSTALLATION & OWNER'S
MANUAL
MODELOS: EBP-06W/1 - EBP-08W/1 - EBP-12W/1 - EBP-14W/1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EBP-06W/1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EAS Electric EBP-06W/1

  • Page 1 SWIMMING POOL INSTALLATION & OWNER'S MANUAL MODELOS: EBP-06W/1 - EBP-08W/1 - EBP-12W/1 - EBP-14W/1...
  • Page 2 IMPORTANT IMPORTANT These installation instructions are an integral part of the product and must be given to the installer and kept by the user. The warnings and indications contained in the present handbook must be carefully read and understood as they provide important information relative to handling and operating safety.
  • Page 3 The main unit of swimming pool water heater Water inlet Water outlet Drain pipe Power cable inlet MODEL: 6kW 8kW 12kW 14kW NOTE All the picture in this manual are for explanation purpose only. They may be slightly different from the water heater you purchased (depend on model).The actual shaped shall prevail.
  • Page 4: Table Of Contents

    Do not insert fingers, rods or other objects into the air inlet or CONTENTS PAGE outlet. When the fan is rotating at high speed, it will cause injury. SAFETY INFORMATION ................Never use a flammable spray such as hair spray, lacquer ACCESSORIES ..................
  • Page 5: Accessories

    2. ACCESSORIES After a long use, check the unit stand and fitting for damage. If damaged, the unit may fall and result in injury. Table 2-1 Accessory name Qty. Shape Purpose To avoid oxygen deficiency,ventilate the room sufficiently if equipment with burner is used together with the water Installation &...
  • Page 6: Installation Of The Unit

    4. INSTALLATION OF THE UNIT 3.1 Precautions before installation: 4.1 Installation Decide the correct way of conveying the equipment. Confirm the model, serial number and name to avoid mistaken Try to transport this equipment with the original package. installation. If the unit needs to be installed on a metal part of the building, The installation must be simple and allow for easy maintenance electric insulation must be performed, and the installation must interventions.
  • Page 7: Pipes Connection Of The Unit

    4.3 Installing the units Table 4-1 MODEL MODEL The spacing of foot screw bolts is shown as following: (unit:mm) 6kW 8kW 1015 1050 12kW 14kW 5. PIPES CONNECTION OF THE UNIT During installation of connective pipe, you must beware not to let any dust or other foreign substance intrude into pipe system.
  • Page 8 Installation diagram for the Swimming Pool Water heater 220-240V~ 50Hz 1ph Water inlet Water outlet Water treatment equipment Swimming Pool Water heater Pump Filter Swimming Pool Fig.5-2 MODEL: 6kW 8kW 12kW 14kW 5.1 Hydraulic connections Connect the appliance’s PVC Ø50 hose water inlet and outlet (according to label instructions) to the removable fittings provided with the heat pump.
  • Page 9: Water Treatment

    Table 6-1 5.2 Water treatment Min. wire size (mm Manual Item (Metal pipe & synthetic switch(A) In order to use our appliances under the best conditions, the resin pipe wire) Power following parameters must be respected: free chlorine: max. RCCB Size supply 2.5 mg/l, total bromine: max.
  • Page 10 H1 H Pump E-heater Here only for signal control,never drive it directly. POWER: 220-240V~ 50Hz Fig.6-2 CAUTION Please don’t reverse connections of low voltage electric signal wire with heavy electric wire, otherwise, some of electric control elements will burned out! The photo of main control board.
  • Page 11: Running And Capability

    Model: 6kW 8kW 12kW 14kW N.C. Tout N.C. N.C. Pro_H Pro_L N.C. Pro_Hyd.O N.C. Fig.6-3 7. RUNNING AND CAPABILITY In order to use the water heating heat pump correctly, please 7.1 About the 3-minute protection ensure that operate is at -7 ~38 outdoor ambient tempera- ture.
  • Page 12 7.6 Start the unit after a long period out of 7.9 About shut-off memory service Every time when power is shut off, controller will save the current operate status automatically. when power come on the next time, Start-up the unit after out of service for a long period (includes controller would deliver ON/OFF signal to the unit according to its drive up a unit at the first time), you would see rust mix up water memory before power failure.
  • Page 13 MODEL: 6kW MODEL: 8kW Heating Mode Heating Mode The curve diagram illustrates the relationship between capacity The curve diagram illustrates the relationship between capacity and corresponding ambient temperature and corresponding ambient temperature 8000 10000 7000 8000 6000 6000 5000 4000 4000 3000 2000...
  • Page 14 MODEL: 12kW MODEL: 14kW Heating Mode Heating Mode The curve diagram illustrates the relationship between capacity The curve diagram illustrates the relationship between capacity and corresponding ambient temperature and corresponding ambient temperature 20000 14000 12000 15000 10000 8000 10000 6000 4000 5000 2000...
  • Page 15: Regulator Operation

    8. REGULATOR OPERATION 8.3 Names of keys on the wire controller 8.1 The introduction of controller's user and the keypad operation description access Control Panel Explanation MODE ON/OFF Fig.8-2 MODE key, used to set different modes UP key, used to add time or temp. DOWN key, used to abate time or temp.
  • Page 16 Temp. Set 8.5 Handling the failure alarm Temp. displayed is the setting Appendix: Fault code list water temp. Default is 28 and the Cool mode setting range is Table 8-2 10~30 the heat mode setting range is 20~35 Malfunction Description Display Method for set Outdoor unit and wire Controller...
  • Page 17: Trial Run

    9. TRIAL RUN Trial run CAUTION Check whether the switch of the controller is normal. Trial run the unit after being powered up for over 12 hours. Check whether the functional keys of the controller are normal. Check that all valves are opened before trial run. Check whether the indicators illuminate normally.
  • Page 18: Specifications

    11. SPECIFICATIONS Table.11-1 Model 12kW 14kW Heating capacity(W) 6000 8000 13600 11700 Heating Standard input(W) 1150 1518 2350 2550 mode Outdoor ambient temperature Cooling capacity(W) 4000 5800 10350 8250 Cooling Standard input(W) 1250 1500 2900 2500 mode Outdoor ambient temperature Max power(W) 1450 1900...
  • Page 19 AFTERSALE SERVICE If the air conditioner was operate abnormally, please plug off the power supply firstly, and contact with After-Sales Center. To consult your nearest technical service, access the website: ELECTRA AIR SOLUTIONS, S.L. www.electrairsolutions.com...

This manual is also suitable for:

Ebp-14w/1Ebp-12w/1Ebp-08w/1

Table of Contents