  • Page 2: Table Of Contents

    INDEX H. Specifications Measurement range 5.5 ~ 99.9% (Digital LCD Display) A. Introductions -------------------------- 1 (% WME) ±1% (difference as the testing B. Features --------------------------------- 1 Accuracy (at 25°C) materials.) Resolution 0.1% C. The Panel and Shape ---------------- 2 Operating Range -10 ~ +50°C (with temp.
  • Page 3: Introductions

    G. Precaution A. Introductions The Moisture Meter M-700 is the complete instrument for 1. The power supply is 9V Battery, and can option to use AC measuring moisture levels in materials. Read moisture reading adaptor. Please notice the power supply when operation. of materials from high accurate digital LCD indicator.
  • Page 5: The Lcd Display

    Calibration Method: D. The LCD Display Turn off the meter. Keep the MODE (CAL) key pressed and press key to turn on the power. When display indicate symbol “CAL” to enter calibration Mode. The indication reading should be 18.4% (±0.5). If need to Low battery calibrate, please use screwdriver to calibrate from right-side MAX Value...
  • Page 6: Operation Instructions

    6. MAX, MIN (Recall): After step 5. MAX.MIN.(Record), E. Operation Instructions press .key to stop record function (display indicates 1. Turn On: Press key to turn on the Meter, It will run to “HOLD”). Press key again to read MAX reading (display set up inside Automatic temperture compensation in few indicates “MAX HOLD”).