TECHNICAL DATA AT CONDITIONS NON STANDARD

2 PIPES
Water Temperature
Air Temperature
IN
OUT
DB
WB
3
6
21
15
3
8
21
15
3
10
21
15
5
8
21
15
5
10
21
15
5
12
21
15
7
10
21
15
7
12
21
15
7
14
21
15
9
12
21
15
9
14
21
15
9
16
21
15
11
14
21
15
11
16
21
15
11
18
21
15
3
6
23
17
3
8
23
17
3
10
23
17
5
8
23
17
5
10
23
17
5
12
23
17
7
10
23
17
7
12
23
17
7
14
23
17
9
12
23
17
9
14
23
17
9
16
23
17
11
14
23
17
11
16
23
17
11
18
23
17
CHILLED WATER FAN COILS – McQuay
012
020
Cooling Capacity
Cooling Capacity
Cooling Capacity
Total
Sens
Total
Sens
[kW ]
[kW]
[kW] [kW]
1.40
1.02
1.91
1.42
1.22
0.89
1.57
1.15
1.01
0.74
1.50
0.86
1.05
0.86
1.44
1.20
0.93
0.75
1.22
0.99
0.79
0.63
0.93
0.76
0.68
0.68
0.98
0.98
0.61
0.61
0.82
0.82
0.52
0.52
0.69
0.64
1.14
0.90
1.54
1.25
0.99
0.78
1.28
1.02
0.83
0.65
0.98
0.77
0.59
0.74
1.06
1.04
0.69
0.65
0.92
0.86
0.77
0.55
0.74
0.66
0.55
0.55
0.80
0.80
0.49
0.49
0.68
0.68
0.42
0.42
0.53
0.53
0.86
0.77
1.15
1.08
0.75
0.68
0.97
0.88
0.63
0.56
0.75
0.66
0.60
0.60
0.86
0.86
0.53
0.52
0.71
0.71
0.45
0.45
0.55
0.55
0.41
0.41
0.62
0.62
0.37
0.37
0.52
0.52
0.32
0.32
0.41
0.41
0.64
0.64
0.89
0.89
0.56
0.56
0.73
0.73
0.47
0.47
0.56
0.56
0.46
0.46
0.67
0.67
0.41
0.41
0.56
0.56
0.35
0.35
0.43
0.43
0.26
0.26
0.42
0.42
0.24
0.24
0.36
0.36
0.21
0.21
0.29
0.29
0.50
0.50
0.70
0.70
0.44
0.44
0.58
0.58
0.37
0.37
0.44
0.44
0.88
0.80
1.37
1.37
0.76
0.76
1.18
1.18
0.60
0.60
0.87
0.87
0.11
0.11
0.21
0.21
0.10
0.10
0.19
0.19
0.09
0.09
0.15
0.15
1.77
1.14
2.42
1.58
1.54
0.99
1.98
1.29
1.27
0.82
1.49
0.96
1.43
0.99
1.96
1.38
1.26
0.86
1.64
1.13
1.06
0.72
1.27
0.86
1.05
0.82
1.47
1.17
0.94
0.73
1.27
0.97
0.81
0.62
1.01
0.75
1.52
1.02
2.06
1.42
1.32
0.89
1.70
1.16
1.09
0.74
1.28
0.87
1.16
0.87
1.60
1.22
1.03
0.77
1.35
1.01
0.87
0.64
1.05
0.76
0.75
0.71
1.07
1.01
0.68
0.63
0.95
0.84
0.60
0.53
0.78
0.65
1.24
0.90
1.68
1.26
1.08
0.79
1.39
1.03
0.90
0.66
1.06
0.77
0.86
0.75
1.18
1.06
0.77
0.66
1.02
0.87
0.66
0.56
0.81
0.67
0.57
0.57
0.83
0.83
0.51
0.51
0.70
0.70
0.44
0.44
0.55
0.55
0.94
0.78
1.26
1.09
0.82
0.68
1.06
0.89
0.69
0.57
0.82
0.67
0.62
0.62
0.88
0.88
0.55
0.55
0.73
0.73
0.46
0.46
0.56
0.56
0.43
0.43
0.64
0.64
0.39
0.39
0.54
0.54
0.33
0.33
0.43
0.43
2.24
2.24
2.88
2.88
1.96
1.88
2.54
2.54
1.46
1.34
2.03
1.97
0.48
0.48
0.68
0.68
0.42
0.42
0.57
0.57
0.36
0.36
0.44
0.44
0.28
0.28
0.44
0.44
0.25
0.25
0.38
0.38
0.22
0.22
0.30
0.30
3 ROWS
025
035
Cooling Capacity
Cooling Capacity
Total
Sens
Total
Sens
Total
[kW ] [kW]
[kW] [kW]
2.66
1.80
3.58
1.49
4.72
1.96
1.33
3.00
2.08
4.01
1.50
1.03
2.25
1.56
2.87
2.22
1.57
2.91
2.17
4.03
1.66
1.19
2.47
1.83
3.47
1.29
0.93
1.89
1.39
2.55
1.70
1.33
2.15
1.82
3.24
1.30
1.02
1.87
1.55
2.84
1.03
0.81
1.47
1.20
2.15
2.25
0.59
2.97
2.20
3.91
1.65
1.18
2.50
1.84
3.34
1.26
0.92
1.88
1.39
2.41
1.78
1.36
2.27
1.88
3.17
1.33
1.03
1.95
1.59
2.76
1.04
0.81
1.51
1.21
2.06
1.20
1.11
1.52
1.52
2.32
0.93
0.86
1.30
1.30
2.07
0.74
0.68
1.04
1.01
1.62
1.80
1.37
2.33
1.90
3.02
1.32
1.02
1.96
1.59
2.61
1.00
0.80
1.48
1.20
1.90
1.28
1.14
1.57
1.57
2.28
0.96
0.87
1.36
1.33
1.98
0.75
0.69
1.07
1.03
1.51
0.86
0.86
1.18
1.18
1.87
0.67
0.67
1.02
1.02
1.61
0.54
0.54
0.80
0.50
1.19
1.30
1.15
1.60
1.60
2.21
0.95
0.86
1.36
1.34
1.87
0.72
0.67
1.04
1.01
1.35
0.90
0.90
1.23
1.23
1.84
0.69
0.69
1.05
1.05
1.57
0.55
0.55
0.82
0.82
1.15
0.59
0.59
0.82
0.82
1.39
0.47
0.47
0.72
0.72
1.21
0.38
0.38
0.57
0.57
0.90
0.91
0.91
1.25
1.25
1.77
0.69
0.69
1.06
1.06
1.50
0.54
0.54
0.81
0.81
1.08
1.77
1.77
0.31
0.31
0.47
1.58
1.58
0.28
0.28
0.40
1.25
1.25
0.24
0.24
0.31
0.28
0.28
0.42
0.42
0.85
0.23
0.23
0.37
0.37
0.75
0.19
0.19
0.31
0.31
0.58
3.26
2.00
4.43
2.78
5.85
2.39
1.48
3.70
2.32
4.96
1.83
1.15
2.76
1.74
3.52
2.84
1.79
3.79
2.47
5.19
2.11
1.34
3.20
2.08
4.44
1.64
1.05
2.43
1.57
3.21
2.35
1.56
3.07
2.14
4.45
1.78
1.19
2.64
1.82
3.85
1.40
0.94
2.04
1.40
2.85
2.86
1.80
3.85
2.50
5.06
2.09
1.33
3.22
2.09
4.30
1.60
1.03
2.41
1.56
3.07
2.42
1.59
3.18
2.19
4.36
1.80
1.20
2.70
1.85
3.76
1.40
0.94
2.06
1.40
2.74
1.89
1.35
2.40
1.86
3.56
1.44
1.03
2.08
1.58
3.12
1.13
0.82
1.63
1.22
2.34
2.42
1.59
3.22
2.21
4.20
1.77
1.18
2.70
1.85
3.59
1.35
0.92
2.02
1.39
2.58
1.94
1.38
2.50
1.90
3.45
1.45
1.04
2.13
1.60
3.00
1.13
0.82
1.64
1.22
2.22
1.35
1.13
1.64
1.56
2.56
1.04
0.87
1.45
1.33
2.29
0.83
0.70
1.17
1.03
1.78
1.94
1.38
2.52
1.91
3.27
1.42
1.03
2.12
1.60
2.81
1.08
0.80
1.60
1.21
2.04
1.42
1.16
1.74
1.59
2.45
1.06
0.88
1.51
1.35
2.17
0.83
0.70
1.18
1.04
1.65
0.89
0.89
1.22
1.22
1.90
0.69
0.69
1.05
1.05
1.64
0.56
0.56
0.82
0.82
1.21
0.65
0.65
0.90
0.90
1.41
0.57
0.57
0.74
0.74
1.03
0.47
0.47
0.56
0.56
0.78
0.92
0.92
1.26
1.26
1.86
0.71
0.71
1.08
1.08
1.59
0.56
0.56
0.83
0.83
1.16
0.62
0.62
0.85
0.85
1.42
0.49
0.49
0.74
0.74
1.23
0.40
0.40
0.59
0.59
0.92
050
060
Cooling Capacity
Cooling Capacity
Sens
Total
Sens
Total
[kW] [kW]
[kW] [kW]
[kW] [kW]
3.40
6.00
4.43
6.96
2.87
5.33
3.89
6.18
2.03
4.17
2.99
4.84
3.07
5.03
3.98
5.83
2.61
4.52
3.51
5.24
1.87
3.62
2.73
4.20
2.71
3.95
3.51
4.58
2.32
3.62
3.11
4.20
1.69
2.99
2.44
3.47
3.01
4.91
3.93
5.70
2.55
4.39
3.45
5.09
1.81
3.46
2.66
4.01
2.69
3.89
3.48
4.51
2.29
3.54
3.08
4.11
1.65
2.89
2.40
3.35
2.32
2.98
2.98
3.46
1.99
2.65
2.65
3.07
1.45
2.19
2.10
2.54
2.62
3.72
3.42
4.32
2.22
3.36
3.00
3.90
1.58
2.70
2.32
3.13
2.28
2.94
2.94
3.41
1.95
2.61
2.61
3.03
1.41
2.07
2.07
2.40
1.87
2.40
2.40
2.78
1.61
2.15
2.15
2.49
1.19
1.71
1.71
1.98
2.21
2.86
2.86
3.32
1.87
2.52
2.52
2.92
1.35
1.96
1.96
2.27
1.84
2.37
2.37
2.75
1.57
2.10
2.10
2.44
1.15
1.66
1.66
1.93
1.39
1.79
1.79
2.08
1.21
1.61
1.61
1.87
0.90
1.29
1.29
1.50
1.77
2.28
2.28
2.64
1.50
2.02
2.02
2.34
1.08
1.57
1.57
1.82
0.47
0.64
0.64
0.74
0.40
0.50
0.50
0.58
0.31
0.40
0.40
0.46
0.85
1.12
1.12
1.30
0.75
1.02
1.02
1.18
0.58
0.83
0.83
0.96
3.76
7.51
4.91
8.71
3.17
6.63
4.30
7.69
2.24
5.15
3.30
5.97
3.45
6.57
4.49
7.62
2.92
5.86
3.95
6.80
2.09
4.63
3.06
5.37
3.12
5.54
4.04
6.43
2.66
5.01
3.57
5.81
1.92
4.04
2.79
4.69
3.39
6.44
4.43
7.47
2.86
5.71
3.88
6.62
2.02
4.46
2.89
5.17
3.08
5.47
4.01
6.35
2.62
4.91
3.53
5.70
1.87
3.91
2.74
4.54
2.74
4.36
3.55
5.06
2.34
3.99
3.15
4.63
1.70
3.27
2.46
3.79
3.01
5.29
3.93
6.14
2.54
4.72
3.45
5.48
1.80
3.72
2.65
4.32
2.70
4.25
3.51
4.93
2.30
3.86
3.09
4.48
1.65
3.13
2.41
3.63
2.35
3.03
3.03
3.51
2.01
2.84
2.70
3.29
1.47
2.42
2.12
2.81
2.62
4.04
3.42
4.69
2.22
3.64
3.01
4.22
1.58
2.91
2.32
3.38
2.30
2.98
2.98
3.46
1.96
2.70
2.64
3.13
1.42
2.27
2.06
2.63
1.90
2.45
2.45
2.84
1.64
2.19
2.19
2.54
1.21
1.74
1.74
2.02
1.16
1.76
1.60
2.04
0.87
1.49
1.35
1.73
0.68
1.13
1.02
1.31
1.86
2.40
2.40
2.78
1.59
2.13
2.13
2.47
1.16
1.68
1.68
1.95
1.42
1.83
1.83
2.12
1.213
1.65
1.65
1.91
0.92
1.32
1.32
1.53
080
090
Cooling Capacity
Sens
Total
Sens
[kW] [kW]
5.05
8.10
5.54
4.43
7.20
4.86
3.41
5.63
3.74
4.54
6.79
4.98
4.00
6.10
4.39
3.11
4.89
3.41
4.00
5.33
4.39
3.55
4.89
3.89
2.78
4.04
3.05
4.48
6.63
4.91
3.93
5.93
4.31
3.03
4.67
3.33
3.97
5.25
4.35
3.51
4.78
3.85
2.74
3.90
3.00
3.40
4.02
3.73
3.02
3.58
3.31
2.39
2.96
2.63
3.90
5.02
4.28
3.42
4.54
3.75
2.64
3.65
2.90
3.35
3.97
3.68
2.98
3.52
3.26
2.36
2.79
2.59
2.74
3.24
3.00
2.45
2.90
2.69
1.95
2.31
2.14
3.26
3.86
3.58
2.87
3.40
3.15
2.23
2.65
2.45
2.70
3.20
2.96
2.39
2.84
2.63
1.89
2.24
2.08
2.04
2.42
2.24
1.84
2.17
2.01
1.47
1.74
1.61
2.60
3.08
2.85
2.30
2.73
2.53
1.79
2.12
1.96
0.73
0.86
0.80
0.57
0.68
0.63
0.46
0.54
0.50
1.28
1.51
1.40
1.16
1.38
1.28
0.95
1.12
1.04
5.60
10.14
6.14
4.90
8.95
5.38
3.76
6.95
4.13
5.12
8.87
5.61
4.50
7.91
4.94
3.49
6.25
3.83
4.61
7.48
5.05
4.07
6.76
4.46
3.18
5.45
3.49
5.05
8.69
5.54
4.42
7.71
4.85
3.29
6.02
3.61
4.57
7.38
5.01
4.02
6.63
4.41
3.12
5.28
3.43
4.05
5.89
4.44
3.59
5.39
3.94
2.80
4.41
3.08
4.48
7.14
4.91
3.93
6.37
4.31
3.02
5.02
3.31
4.00
5.74
4.39
3.52
5.21
3.86
2.75
4.23
3.01
3.45
4.09
3.79
3.08
3.83
3.38
2.42
3.27
2.65
3.90
5.45
4.28
3.43
4.91
3.76
2.64
3.93
2.90
3.40
4.02
3.73
3.01
3.65
3.30
2.35
3.06
2.58
2.79
3.31
3.06
2.50
2.96
2.74
1.98
2.35
2.18
1.82
2.38
2.00
1.54
2.01
1.69
1.16
1.53
1.28
2.74
3.24
3.00
2.43
2.88
2.66
1.92
2.27
2.10
2.09
2.47
2.29
1.88
2.23
2.06
1.50
1.78
1.65
26