CTC Union MMX-MOD3 Series Installation Manual
CTC Union MMX-MOD3 Series Installation Manual

CTC Union MMX-MOD3 Series Installation Manual

Advertisement

Quick Links

Installation Manual
MNX10033 / REV 0
MODEL MMX-MOD3 Series
MAXX Box Module, 3 BNC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMX-MOD3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for CTC Union MMX-MOD3 Series

  • Page 1 Installation Manual MNX10033 / REV 0 MODEL MMX-MOD3 Series MAXX Box Module, 3 BNC...
  • Page 2: Table Of Contents

    Contents SECTION I OVERVIEW ..........................2 .............................. 2 NTRODUCTION ..............................2 ESCRIPTION SECTION II INSTALLATION........................3 ..............................3 ESCRIPTION ..........................3 LECTRICAL ONNECTIONS 1. P ..................... 3 IGURE LACEMENT OF EMOVABLE LUGS 2. D ........................3 IGURE WITCH ETTINGS ....................4 IRING UTPUT AND RIAXIAL ENSORS...
  • Page 3: Section I Overview

    Section I Overview Introduction This document will explain the operation, setup, installation and maintenance of the MMX-MOD3 modules, for use with vibration sensors. This module will take the input from up to three separate single axis, 2 wire sensors, one dual output sensor (vibration/temperature or 4-20mA/vibration) where the common is shared between the dual output sensor input, or one triaxial output sensor, where the “common”...
  • Page 4: Section Ii Installation

    Section Installation Description The MMX-MOD3 module is intended to be installed inside a protective enclosure. This minimizes the effects of the environment contaminating the BNC jacks or the pc board, and assures better data collection. CTC offers our MMX1000/2000 Series Enclosures for this purpose. Electrical Connections The orientation of the removable plugs has BNC #1 with plug closest to the DIN rail mount (or bottom) on the module, with #2 in the middle and #3 will be nearest...
  • Page 5: W Iring D Ual O Utput And T Riaxial S Ensors

    Note: Module is set at “Commons Shared – OPEN” at factory Once the proper settings are made to the module, it is ready for service. Dipswitch Figure 3. MMX-MOD3 Layout Wiring Dual Output and Triaxial Sensors Dual Out and Triaxial sensors can be wired into the MMX-MOD3 by setting the dipswitch to the appropriate settings and wiring the inputs as shown in the table below.
  • Page 6: Section Iii Operation

    Section III Operation Once the dip switch is set and the sensors are attached correctly to the inputs, the unit is ready for use. Access the signal from the sensors through the appropriate BNC’s. Section Maintenance General There are no customer replaceable parts. The device has been designed to self calibrate and monitor its own operational status.

Table of Contents