Read and perform this adjustment when repairing the
circuits or replacing electrical parts or PCB assemblies.
1. BASIC ADJUSTMENT
1-1: SWITCHING POINT
CONDITIONS
MODE-PLAYBACK
Input Signal-Alignment Tape (MHP)
INSTRUCTIONS
1.
Connect CH-1 on the oscilloscope to TP3002 and CH-2
to TP8001.
2.
Playback the alignment tape. (MHP)
3.
Press and hold the Tracking-Auto button on the remote
control more than 2 seconds to set tracking to center.
4.
Press both CH UP button on the set and the STOP button
on the set for more than 2 seconds.
ELECTRICAL ADJUSTMENT PARTS LOCATION GUIDE
J8001 J8008 J8006 J8009 J8007 OS8001
TP8001
TU301
TP101
TP3002
J8003 J8004 J8005
ELECTRICAL ADJUSTMENTS
TP3001
VCR MT PCB
6.5H
6.5H
TP101 : Envelope
TP3001 : Service Mode
TP3002 : Switching Pulse
TP8001 : Switching Point
V651
CH-2
CH-1
Fig. 1-1-A
CH-2
CH-1
Fig. 1-1-B
1-23