Page 1
CENTRALE DI COMANDO - CONTROL UNIT H70/103AC ISTRUZIONI E AVVERTENZE PER L’INSTALLATORE INSTRUCTIONS AND RECOMENDATIONS FOR THE INSTALLER INSTRUCÇÕES E ADVERTÊNCIAS PARA A INSTALAÇÃO ISTRUCTIONS ET AVERTISSEMENT POUR L’INSTALLATEUR IS36 Rev.02 21/07/2011 H70/103AC...
Page 2
TECHNICAL DETAILS 1 motor 230V~ ±10% 50Hz, 2200W max Courtesy 2A max (tension free contact) Working temperature from -10 to +55°C Open gate led 24Vcc 2W max Flashing light 1A max (tension free contact ) Accessories current 300mA max on 24Vcc ...
Page 3
PARAMETER CHANGE MODE If we select the parameter to be modified, pushing the button S3 we can modified the parameter. If the control unit is protected by password, the parameter could be only showed but not modified, we can modified the parameter if we enter the password (P1,P2,P3,P4).
Page 4
Parameter Description of parameter function Default Value Number parameter value → Behaviour of the parameter INPUT Showing of input status (picture 5) Configuration level 0 → BASIC shows You only a part of the parameters (ones not marked by A) 1 →...
Page 5
Torque level of the start up after an inversion due to safety edge or anticrushing 0 → start up not enable, the gate inverts with the torque settled during the normal travel 1-8 → LEVEL (1 = minimum... 8 = maximum) Start up times 1-20 →...
Page 6
Enables breaking before an inversion (AP–CH o CH–AP) 0 → NOT breaking before the inversion 1 → breaking before the inversion Breaking time 1-99 → breaking time on DECIMAL SECONDS Breaking force 1-8 → LEVEL (1 = minimum... 8 = maximum) Motor position on the gate.
Page 7
Recover setting default To recover all parameters setted on Roger Technology (look the last column of this table), You have to push the selection button and after the 2 scrolling buttons togheter. If this process is done in the correct way the display shows You the parameter LL..
Page 8
CONNECTIONS TABLE AP – COM normally open contact OPEN INPUT BUTTON CH – COM normally open contact CLOSE INPUT BUTTON PED – COM normally open contact PEDESTRIAN OPENING INPUT BUTTON ORO – COM normally open contact CLOCK INPUT central pole of the cable ANTENNA shield We recommend the use of RG58 coaxial cable (50Ω)
Page 9
4 SELECTION BUTTON SCROLLING BUTTON H70/103AC RELEASE COM - COMMON INPUT - OPEN - CLOSE LIMIT PED - PEDESTRIAN SWITCH ORO - CLOCK INPUT Radio receiver ANT - ANTENNA COM - COMMON ENCODER INPUT Fuse 0,5A FAST - STEP BY STEP...
Need help?
Do you have a question about the H70/103AC and is the answer not in the manual?
Questions and answers