• When carrying out piping connection, make sure not to get any substance into the refrigerant lines,
otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
• DO NOT modify the length of the power supply cord or use of extension cord, and DO NOT share the
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
• If the refrigerant leaks during installation, ventilate the area immediately. Toxic gas may be produced if
the refrigerant comes into the place contacting with fire.
• The temperature of refrigerant circuit will be high, please keep the interconnection cable away from
the copper tube.
• After completing the installation work, check that the refrigerant does not leak. Toxic gas may be
produced if the refrigerant leaks into the room and comes into contact with a source of fire, such as a
fan heater, stove or cooker.
CAUTION
GROUND THE AIR CONDITIONER
• DO NOT connect the ground wire to gas or water
pipes, lightning rod or a telephone ground wire.
Inappropriate grounding may result in electric shocks.
• Be sure to install an earth leakage breaker. Failure
to install an earth leakage breaker may result in
electric shock.
• Connect the outdoor unit wires, then connect the
indoor unit wires. You are not allowed to connect
the air conditioner with the power supply until
the wiring and piping is done.
• While following the instructions in this
installation manual, install drain piping in order
to ensure proper drainage and insulate piping
in order to prevent condensation. Improper drain
piping may result in water leakage and property
damage.
• Install the indoor and outdoor units, power supply
wiring and connecting wires. They should be at
least 40" away from televisions or radios in order
to prevent image interference or noise.
• Don't install the air conditioner in the following
circumstance:
a) There is petrolatum existing
b) There is caustic gas (the sulfide, for example)
existing in the air (near a hot spring)
c) The Volt vibrates violently (in the factories)
d) There is strong electromagnetic wave existing
e) There are flammable materials or gas
f) There is acid or alkaline liquid evaporating
g) Other special conditions
• The appliance shall be installed in accordance
with national wiring regulations.
• An all-pole disconnection device which has at
least 3mm/0.118" clearances in all poles, and
have a leakage current that may exceed 10mA,
the residual current device (RCD) having a rated
residual operating current not exceeding 30mA,
and disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules.
INSTALLATION INFORMATION
• Prior to installing, please read this "installation
manual" thouroughly.
• The air conditioner must be installed by qualified
persons.
• When installing the indoor unit or its tubing,
please follow this manual as strictly as possible.
• If the air conditioner is installed on a metal
portion of the building, it must be electrically
insulated according to the relevant standards to
electrical appliances.
• When all the installation work is finished, please
turn on the power only after a thorough check.
INSTALLATION ORDER
• Indoor unit installation.
• Outdoor unit installation.
• Install the refrigerant pipe.
• Connect the drain pipe.
• Electric wiring work.
• Installation of the decoration panel.
• Test operation.
4