Ideal Air 700021 Installation Manual

Pro/dual mini-split slip-type room air conditioner
Hide thumbs Also See for 700021:

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Ideal Air 700021

  • Page 5 Name Shape Quantity Mounting plate Clip anchor Mounting plate fixing screw ST3.9 X 25 Remote control Fixing screw for remote controller holder ST2.9 x 10 Optional Parts Remote controller holder Dry battery AAA.LR03 Seal Drain joint User manual Installation manual 6.35( 1/4 “) Liquid side...
  • Page 6 15cm (5.9”) 12cm 12cm (4.75”) (4.75”) 2.3m (90.55”) Select Installation Location Attach Mounting Plate (Page 9) (Page 10) Determine Wall Hole Position... And Drill Wall Hole (Page 10) (Page 10) Prepare Refrigerant Piping (Page 12)
  • Page 7 Connect Drain Hose Connect Signal Cable (Page 13) (Page 14) Wrap Piping and Cable (Page 15) STEP Mount Indoor Unit (Page 16)
  • Page 8: Wall Mounting Plate

    Wall Mounting Plate Front Panel Drainage Pipe Louver Signal Cable Functional Filter (On Front of Main Refrigerant Filter - Some Units) Piping Outdoor Power Cable (Some Units) Remote Control Remote Holder (Some Units)
  • Page 10 15cm/5.9” or more 12cm/4.75” 12cm/4.75” or more or more 2.3m/90.55” or more Wall Indoor Outdoor...
  • Page 11 348.4mm/13.7” 517.4mm/20.37” 179mm/7.05” 144mm/5.65” 138mm/5.45” 101mm/4” 136mm/5.35” 34mm/1.35”/ 965mm/38” 722mm/28.45” Right rear wall Model C Right rear wall hole 65mm/2.5” hole 65mm/2.5” 426mm/16.8” 553mm/21.77” 232mm/9.15” 300mm/11.8in 219mm/8.6” 192mm/7.55” 128mm/5.05” 76mm/3” 148.7mm /5.85” 47mm/1.85” 174.3mm/6.85” 151mm/5.95” 1080mm/42.5” 802mm/31.6” Model D Right rear wall Right rear wall Left rear wall Left rear wall hole...
  • Page 12 Knock-out Panel...
  • Page 13 CORRECT NOT CORRECT Kinks in the drain hose Make sure there are no will create water traps. kinks or dent in drain hose to ensure proper drainage. NOT CORRECT Do not place the end NOT CORRECT of the drain hose in water or in containers Kinks in the drain hose that collect water.
  • Page 14: Other Regions

    North America Other Regions Rated Current of Nominal Cross-Sectional Appliance Amps (A) Area (mm²)/in Appliance (A) > 3 and ≤ 6 0.75/.03” > 6 and ≤ 10 1/.28” > 10 and ≤ 16 1.5/.06” > 16 and ≤ 25 2.5/.10” >...
  • Page 15 Indoor Unit Terminal block Wire cover Space behind unit Refrigerant piping Screw Cable clamp Insulation tape Drain hose Signal wire The Wiring Diagram is located on the inside of the indoor unit’s wire cover.
  • Page 16 30-50mm 30-50mm (1.2-1.95”) (1.2-1.95”) Move to left or right...
  • Page 17 Strong wind Strong wind Wind baffle Strong wind...
  • Page 18: Air Inlet

    Air inlet Air inlet Air outlet Outdoor Unit Dimensions (mm/in) Mounting Dimensions W x H x D Distance A (mm/in) Distance B (mm/in) 681x434x285 (26.8”x17”x11.2”) 460 (18.10”) 292 (11.49”) 700x550x270 (27.5”x21.6”x10.62”) 450 (17.7”) 260 (10.24”) 780x540x250 (30.7”x21.25”x9.85”) 549 (21.6”) 276 (10.85”) 845x700x320 (33.25”x27.5”x12.6”) 560 (22”) 335 (13.2”)
  • Page 20 North America Appliance Amps (A) Other Regions Rated Current of Nominal Cross- Appliance (A) Sectional Area (mm²)/in > 3 and ≤ 6 0.75/.03” > 6 and ≤ 10 1/.04” > 10 and ≤ 16 1.5/.06” > 16 and ≤ 25 2.5.10”...
  • Page 21 Model Capacity (BTU/h) Max. Length (m) Max. Drop Height (m) < 15,000 25 (82’) 10 (33’) ≥ 15,000 and < 24,000 30 (98.5’) 20 (66’) R410A Inverter Split Air Conditioner ≥ 24,000 and < 36,000 50 (164’) 25 (82’) ≥ 36,000 and ≤ 60,000 65 (213’) 30 (98.5’)
  • Page 22 Radius ≥10cm/4” Outer Diameter of A (mm) Pipe (mm) Min. Max. Ø 6.35 (Ø 0.25”) 0.7 (0.0275”) 1.3 (0.05”) Ø 9.52 (Ø 0.375”) 1.0 (0.04”) 1.6 (0.063”) Ø 12.7 (Ø 0.5”) 1.0 (0.04”) 1.8 (0.07”) Ø 16 (Ø 0.63”) 2.0 (0.078”) 2.2 (0.086”)
  • Page 23 TORQUE REQUIREMENTS Outer Diameter of Pipe (mm) Tightening Torque (N•cm) Add. Tightening Torque (N•m) Ø 6.35 (Ø 0.25”) 1,500 (11lb •ft) 1,600 (11.8lb •ft) Ø 9.52 (Ø 0.375”) 2,500 (18.4lb •ft) 2,600 (19.18lb •ft) Ø 12.7 ( Ø 0.5”) 3,500 (25.8lb•ft) 3,600 (26.55lb•ft) Ø...
  • Page 24 ADDITIONAL REFRIGERANT PER PIPE LENGTH Connective Pipe Air Purging Additional Refrigerant Length (m) Method < Standard pipe length Vacuum Pump Liquid Side: Ø 6.35 (ø 0.25”) Liquid Side: Ø 9.52 (ø 0.375”) R22: R22: (Pipe length – standard length) x 30g/m (Pipe length –...
  • Page 25 List of Checks to Perform PASS/FAIL No electrical leakage Unit is properly grounded All electrical terminals properly covered Indoor and outdoor units are solidly installed All pipe connection Outdoor Indoor points do not leak (2): (2): Water drains properly from drain hose All piping is properly insulated Unit performs COOL...
  • Page 26 Manual control button...