Wall Mounting Plate Front Panel Drainage Pipe Louver Signal Cable Functional Filter (On Front of Main Refrigerant Filter - Some Units) Piping Outdoor Power Cable (Some Units) Remote Control Remote Holder (Some Units)
Page 10
15cm/5.9” or more 12cm/4.75” 12cm/4.75” or more or more 2.3m/90.55” or more Wall Indoor Outdoor...
Page 11
348.4mm/13.7” 517.4mm/20.37” 179mm/7.05” 144mm/5.65” 138mm/5.45” 101mm/4” 136mm/5.35” 34mm/1.35”/ 965mm/38” 722mm/28.45” Right rear wall Model C Right rear wall hole 65mm/2.5” hole 65mm/2.5” 426mm/16.8” 553mm/21.77” 232mm/9.15” 300mm/11.8in 219mm/8.6” 192mm/7.55” 128mm/5.05” 76mm/3” 148.7mm /5.85” 47mm/1.85” 174.3mm/6.85” 151mm/5.95” 1080mm/42.5” 802mm/31.6” Model D Right rear wall Right rear wall Left rear wall Left rear wall hole...
Page 13
CORRECT NOT CORRECT Kinks in the drain hose Make sure there are no will create water traps. kinks or dent in drain hose to ensure proper drainage. NOT CORRECT Do not place the end NOT CORRECT of the drain hose in water or in containers Kinks in the drain hose that collect water.
North America Other Regions Rated Current of Nominal Cross-Sectional Appliance Amps (A) Area (mm²)/in Appliance (A) > 3 and ≤ 6 0.75/.03” > 6 and ≤ 10 1/.28” > 10 and ≤ 16 1.5/.06” > 16 and ≤ 25 2.5/.10” >...
Page 15
Indoor Unit Terminal block Wire cover Space behind unit Refrigerant piping Screw Cable clamp Insulation tape Drain hose Signal wire The Wiring Diagram is located on the inside of the indoor unit’s wire cover.
Page 16
30-50mm 30-50mm (1.2-1.95”) (1.2-1.95”) Move to left or right...
Air inlet Air inlet Air outlet Outdoor Unit Dimensions (mm/in) Mounting Dimensions W x H x D Distance A (mm/in) Distance B (mm/in) 681x434x285 (26.8”x17”x11.2”) 460 (18.10”) 292 (11.49”) 700x550x270 (27.5”x21.6”x10.62”) 450 (17.7”) 260 (10.24”) 780x540x250 (30.7”x21.25”x9.85”) 549 (21.6”) 276 (10.85”) 845x700x320 (33.25”x27.5”x12.6”) 560 (22”) 335 (13.2”)
Page 20
North America Appliance Amps (A) Other Regions Rated Current of Nominal Cross- Appliance (A) Sectional Area (mm²)/in > 3 and ≤ 6 0.75/.03” > 6 and ≤ 10 1/.04” > 10 and ≤ 16 1.5/.06” > 16 and ≤ 25 2.5.10”...
Page 21
Model Capacity (BTU/h) Max. Length (m) Max. Drop Height (m) < 15,000 25 (82’) 10 (33’) ≥ 15,000 and < 24,000 30 (98.5’) 20 (66’) R410A Inverter Split Air Conditioner ≥ 24,000 and < 36,000 50 (164’) 25 (82’) ≥ 36,000 and ≤ 60,000 65 (213’) 30 (98.5’)
Page 24
ADDITIONAL REFRIGERANT PER PIPE LENGTH Connective Pipe Air Purging Additional Refrigerant Length (m) Method < Standard pipe length Vacuum Pump Liquid Side: Ø 6.35 (ø 0.25”) Liquid Side: Ø 9.52 (ø 0.375”) R22: R22: (Pipe length – standard length) x 30g/m (Pipe length –...
Page 25
List of Checks to Perform PASS/FAIL No electrical leakage Unit is properly grounded All electrical terminals properly covered Indoor and outdoor units are solidly installed All pipe connection Outdoor Indoor points do not leak (2): (2): Water drains properly from drain hose All piping is properly insulated Unit performs COOL...