8.3

junction box installation

Remove the two screws that secure the junction box assembly
A.
EN
to the outer shell on the left side of the appliance and remove
the junction box assembly.
Remove the one screw that secures the junction box to the
B.
junction box plate and slide off the clip.
Route the supply wire through the 7/8" (22mm) hole of the
C.
junction box plate with a box connector (not supplied).
Connect the 120 volt supply wire to the receptacle as per the
D.
CSA C22.1 Canadian Electrical Code in Canada or the ANSI/
NFPA 70-1996 National Electrical Code in the United States.
Once the wiring is complete, reinstall the junction box to the
E.
junction box plate and resecure the screw that was removed
in step B.
Reinstall the junction box assembly by reversing step A
F.
making sure all plugs are secure in the junction box.
NOTE: If the appliance is already installed inside the enclosure, you can access the junction box from
inside the appliance by removing the burner base assembly, see "ACCESSING THE BLOWER" section.
8.4

wiring diagram

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED
SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE
APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,

8.4.1 wiring requirements

This appliance must be electrically connected and grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996
NATIONAL ELECTRICAL CODE in the United States.
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA 70-1996 national
electrical code in the United States.
W415-2197 / A / 09.14.17
WARNING
!
ELECTRICAL CIRCUIT.
THE UNITED STATES.
WITH THE GLASS DOOR OPENED OR REMOVED.
B
1
B
2
A
69.2_2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd46pt-2Hd40nt-2Hd40pt-2Hd46nt-2Hd35pt-2

Table of Contents