1
About this document
11 Function                                              1
12 Target group: authorised qualified personnel                 1
13 Explanation of the symbols used                           1
14 Appropriate use                                        1
15 General safety instructions                               1
16 Warning about misuse                                   2
17 Exclusion of liability                                     2
2
Product description
21 Ordering code                                         2
22 Special versions                                       2
23 Comprehensive quality insurance to 2006/42/EC              2
24 Destination and use                                     2
25 Technical data                                         3
26 Safety classification                                     3
3
Mounting
31 General mounting instructions                             3
32 Dimensions                                           4
33 Switching distance                                      4
34 Adjustment                                            4
4
Electrical connection
41 General information for electrical connection                 5
42 Serial diagnostic -SD                                    5
5
Operating principles and coding
51 Mode of operation of the safety outputs                     5
52 Coding                                               5
6
Diagnostic functions
61 Operating principle of the diagnostic LED's                   6
62 Operating principle of the electronic diagnostic output           6
63 Safety-sensors with serial diagnostic function                 7
SHOP ONLINE at www.airlinehyd.com
7
Set-up and maintenance
71 Functional testing                                      8
72 Maintenance                                          8
8
Disassembly and disposal
81 Disassembly                                          8
82 Disposal                                              8
9
Appendix
91 Wiring configuration and connector accessories               8
92 Wiring examples                                       9
10 EU Declaration of conformity
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer Detailed information regarding the range of applications
can be found in the chapter "Product description"
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, labelled with the caution or warning symbol above,
the country-specific installation standards as well as all prevailing safety
regulations and accident prevention rules
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
wwwschmersalnet
EN
RSS 36 / RST 36-1
1
800-999-7378

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RST 36-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal RST 36-1

  • Page 1 Diagnostic functions Further technical information can be found in the Schmersal 61 Operating principle of the diagnostic LED's                   6...
  • Page 2: Product Description

    2.3 Comprehensive quality insurance to 2006/42/EC provided without liability and is subject to technical modifications Schmersal is a certified company to appendix X of the Machinery Directive As a result, Schmersal is entitled to autonomously conduct There are no residual risks, provided that the safety instructions as well...
  • Page 3: Ambient Conditions

    Operating instructions Safety sensor RSS 36 / RST 36-1 2.5 Technical data 2.6 Safety classification Standards: IEC 60947-5-3, ISO 13849-1, Standards: ISO 13849-1, IEC 61508, IEC 62061 IEC 61508, IEC 62061 Enclosure: glass-fibre reinforced thermo- Control Category: plastic, self-extinguishing PFH value:...
  • Page 4 Operating instructions Safety sensor RSS 36 / RST 36-1 3.2 Dimensions The side allows for a maximum height misalignment (X) of sensor All measurements in mm and actuator of ± 8 mm (eg mounting tolerance or due to guard door sagging) The axial misalignment (y) is max ±...
  • Page 5: Electrical Connection

    After fault rectification, the error message is reset by opening and Information for the selection of suitable safety-monitoring re-closing the corresponding safety guard The safety outputs enable modules can be found in the Schmersal catalogues or in the and allow a restart online catalogue on the Internet: wwwschmersalnet...
  • Page 6: Diagnostic Functions

    Operating instructions Safety sensor RSS 36 / RST 36-1 6. Diagnostic functions 6.2 Operating principle of the electronic diagnostic output A diagnostic output additionally indicates the operating condition 6.1 Operating principle of the diagnostic LED's (refer to table 1) These signals can be used in a downstream control...
  • Page 7 PLC The necessary documentation for the integration of the SD- safety outputs are only deleted upon the next release, as the fault Gateway is available for download at wwwschmersalcom rectification cannot be detected sooner The response data and the diagnostic data are automatically and...
  • Page 8 Operating instructions Safety sensor RSS 36 / RST 36-1 7. Set-up and maintenance 8. Disassembly and disposal 7.1 Functional testing 8.1 Disassembly The safety function of the safety components must be tested The safety switchgear must be disassembled in a de-energised...
  • Page 9 Operating instructions Safety sensor RSS 36 / RST 36-1 9.2 Wiring examples The application examples shown are suggestions They however do not release the user from carefully checking whether the switchgear and its set-up are suitable for the individual application...
  • Page 10: Eu Declaration Of Conformity

    Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at wwwschmersalnet K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

This manual is also suitable for:

Rss 36

Table of Contents