Operation And Maintenance - Superior WRE3042WS Installation And Operation Instructions Manual

Residential and outdoor wood-burning fireplace
Table of Contents

Advertisement

OPTIONAL GAS LINE INSTALLATION Continued
If you install a decorative gas appliance (vented gas log), decorative
gas appliance must comply with the Standard for Decorative Gas
Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI
Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance
with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/
CGA-B149.1 National Gas And Propane Installation Code (Canada).
Outside of Fireplace
Gas Line
Conduit
Insulation
Gas
Conduit
Cover
Figure 19 - Gas Line Knockout
Outside of
Fireplace
Gas
Line
Conduit
Repack
Insulation
Figure 20 - Gas Line Installation
WARNING: To avoid the risk of damaging fireplace
materials and increasing the risk of spreading a fire,
do not use fireplace to cook or warm food.
WARNING: If the fireplace has been used for wood
burning, firebox and chimney must be cleaned of soot,
creosote and ashes be a qualified chimney cleaner.
Creosote will ignite if heavily heated.
WARNING: When using a decorative vented gas
log, damper must be removed or permanently locked
in fully open position and glass doors must be in fully
open position.
127055-01E
Side
Firebrick
Finished
Side
1/2" Dowel
Refractory
Knockout
Plug
Side
Incoming
Firebrick
1/2" Black
Finished
Iron Pipe
Side
Seal
Opening
Provide Enough
with
Threaded End for
Refractory
Fitting Connection
Cement
Superiorfireplaces.US.com

OPERATION AND MAINTENANCE

GLASS DOORS
Glass doors are optional with this fireplace. When fireplace is in
operation, doors must be fully opened or fully closed position only
or a ire hazard may be created (see Figure 21).
A fireplace equipped with glass doors operates much differently than
a fireplace with an open front. A fireplace with glass doors has a
limited amount of air for combustion. Excessive heat within ireplace
can result if too large a fire is built or if combustion air gate is not
completely open.
The following tips should be used to assure that both fireplace and
glass door retain their beauty and function properly. Both the flue
damper and glass doors must be fully opened before starting a
fire. This will provide sufficient combustion air and maintain safe
temperatures in firebox.
IMPORTANT: The glass must be allowed to warm slowly and evenly.
Tempered glass will withstand a gradual temperature rise to 550°
F, which is more than a normal fire will generate. Such materials as
pitch/wax laden logs, very dry mill end lumber and large amounts
of paper or cardboard boxes can create an excessively hot fire and
should not be burned in this fireplace. Always keep fire back from
doors and never allow flames to contact glass.
WARNING: FIREPLACES EQUIPPED WITH DOORS
SHOULD BE OPERATED ONLY WITH DOORS FULLY
OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT
PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT
OF THE FIREPLACE OPENING, CREATING RISKS OF
BOTH FIRE AND SMOKE.
WARNING: Discontinue use of the appliance imme-
diately if doors are damaged and contact a qualified
installer for repair. Only doors certified with the
appliance shall be used.
WARNING: Do not slam or strike doors. Damage
can result in a hazardous condition.
Doors Fully Closed
Fireplace Front
Doors Fully Opened
Fireplace Front
Figure 21 - Glass Doors
Cleaning Glass
Clean glass with any commercial glass cleaner or soap and water.
Do not use any abrasive material to clean the glass. Do not clean
glass with any cool water if glass is still hot from fire and smoke.
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wre3042whWre3042rhWre3042rs

Table of Contents