Superior WRE3836WS Installation And Operation Instructions Manual

Wood-burning outdoor fireplace

Advertisement

Quick Links

P/N 127023-01 Rev. A 02/2014
P127023-01
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains
information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other
important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This wood burning fireplace complies with
UL127 CAN/ULC-S610-M87 standard as a
FACTORY BUILT FIREPLACE.
This fireplace is approved for use as a wood furning fireplace or for use with a vented gas log approved to
ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a
permit.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Superior
PFS
Models
®
C
US
WRE3836WS
SAVE THIS BOOK
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Ce foyer au bois est conforme aux UL 127 CAN/ULC-
S610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
POUR LE CANADA: L'autorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l'installation afin de déterminer la
nécessité d'obtenir un permis.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
Wood-Burning Outdoor Fireplace
TM
WRE3836WH
WRE3836RS
WRE3836RH

Advertisement

Table of Contents
loading

Summary of Contents for Superior WRE3836WS

  • Page 1 Installation and Operation Instructions Superior Wood-Burning Outdoor Fireplace P/N 127023-01 Rev. A 02/2014 Models ® WRE3836WS WRE3836WH WRE3836RS WRE3836RH P127023-01 SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed.
  • Page 2 CATALYTIC FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL ® CATALYTIC FIREPLACE 36" WOOD BURNING OUTDOOR FIREPLACE These models meet the EPA Wood Burning Fireplace Program Phase 2 emission level. NOTE: To ensure proper fireplace operation, the catalyst should be replaced at a minimum of 3 years and a maximum of 5 years.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety ..............3 HearthCAT™Emissions Control System ... 17 Specifications ............4 Parts ..............19 Fireplace Installation..........5 Replacement Parts ..........21 Venting Installation ..........7 Technical Service..........22 PureFire Installation........... 14 Accessories ............22 Optional Gas Line Installation......14 Warranty ............
  • Page 4: Specifications

    SPECIFICATIONS GAS LINE RIGHT SIDE KNOCK ELECTRICAL OUTS OUTLET 1" AIRSPACE TO COMBUSTIBLE MATERIAL 0" TO NO COMBUSTIBLE 9.125" 3.5" MATERIAL ON FACE SPACERS 7.092" 8.717" AIR KIT 11.217" KNOCK OUT LEFT SIDE GAS LINE KNOCK COMBUSTIBLE OUTS WALL BOARD 0.75"...
  • Page 5: Fireplace Installation

    FIREPLACE INSTALLATION SELECTING LOCATION 2. If fireplace is to be installed directly on carpeting, tile (other than ceramic) or any To determine safest and most efficient location combustible material other than wood for fireplace, you must take into consideration flooring, fireplace must be installed upon the following guidelines: a metal or wood panel extending full width 1.
  • Page 6 FIREPLACE INSTALLATION DRAIN PAN (DP36) WARNING: Hearth extension For outdoor installations, the fireplace enclo- is to be installed only as shown sure must allow for adequate drainage and in Figure 3. fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the Seal Gap fireplace within the fireplace enclosure (see...
  • Page 7: Venting Installation

    FIREPLACE INSTALLATION Continued MANTELS Mantels or any other combustible material also may come up to the side edge of the A mantel may be installed if desired (see stainless steel face of the fireplace just as long Figures 4 and 5). Woodwork such as wood as the projection from the front face fall within trims, mantels or any other combustible the limit shown in Figure 4 and 5.
  • Page 8 VENTING INSTALLATION Continued Secure to Collars with Metal Tape, Screws " or Straps (Min. of 1/4" x 20" in size) Galvanized Outer Pipe Air Inlet Hemmed Location Must Allow 8" Stainless For Bushes Inner Pipe or Snow LINEAL GAIN PART NO. DESCRIPTION GAIN 36"...
  • Page 9 VENTING INSTALLATION Continued Continue to assemble chimney sections as 2. Chimney weight above offset rests on outlined, making sure that both inner and return elbow. Straps must be securely outer pipe sections are locked together. When nailed to rafters or joists (see Figure 9, installing double wall snap-lock chimney to- details A and B on page 9).
  • Page 10 VENTING INSTALLATION Continued See Detail A Ceiling Support Pipe 12S-8DM 2" Min. See Detail B Straps Straps Straps Straps Detail A Detail B Return Elbow Angle Firestop Figure 9 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH 48" 36" 24" 18" 12" "...
  • Page 11 VENTING INSTALLATION Continued FIRESTOP SPACERS (3600FS-8DM-1) 4. Remove shingles around opening mea- sured. Cut out this section. Firestop spacers are required at each point 5. Add next sections of pipe until end where chimney penetrates a floor space. penetrates roof line. Check to see that Their purpose is to establish and maintain proper clearances are maintained.
  • Page 12 VENTING INSTALLATION Continued Terminations with 16" slip pipe sections are Overlap Storm Collar Shingles Top available. RTT-8DM, RTTL-8DM and RLTT- Flashing and Sides Only 8DM are approved for flashing installations. Cone When needed, these adjustable terminations Nail Only may be used in combination with pipe assem- Outer bly to achieve correct chimney height.
  • Page 13: Finishing The Fireplace

    VENTING INSTALLATION Continued Level of Flue Gas Outlet 18" Min. 2' Min. Typ. 3' Min. 2' Min. 3' Min. 24" Min. Figure 18 - 10 Foot Rule 24" Min. FINISHING THE FIREPLACE Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, Figure 17 - Multiple Chase Installation etc.
  • Page 14: Purefire Installation

    PUREFIRE HOOD INSTALLATION 1. The PureFire hood supplied with this fire- Hood Refractory place is packaged in a separate box and Retainer placed in the firebox during shipping. 2. Remove hood from box. 3. Lift the hood up into the fireplace at an angle with the rear facing up.
  • Page 15: Operation And Maintenance

    OPTIONAL GAS LINE INSTALLATION Continued If you install a decorative gas appliance CAUTION: All gas piping and (vented gas log), decorative gas appliance connections must be tested for must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel leaks after installation is com- Burning Fireplaces, ANS Z21.60 or Z21.84 pleted.
  • Page 16 OPERATION AND MAINTENANCE Continued OUTSIDE AIR AND DAMPER WARNING: Fireplaces HANDLE OPERATION equipped with glass doors Damper handle, which opens and closes should be operated only with damper blade, is located in upper front face doors fully opened or doors fully of fireplace.
  • Page 17 Fireplaces with lower emissions produce less smoke when installed and operated properly. the back of the grate. Use clean dry wood, seasoned cord wood is the best choice. MANUFACTURER: INNOVATIVE HEARTH PRODUCTS, LLC MODEL NO: WRE3836WS Never burn trash, plastics, gasoline, rubber, WRE3836WH WRE3836RS WRE3836RH industrial solvents, flammable liquids, naptha, PARTICLE EMISSIONS: 4.8 GRAMS/KG OF WOOD BURNED...
  • Page 18 PUREFIRE EMISSION CONTROL SYSTEM Continued WARRANTY The smoke that is usually seen coming out of a chimney is essentially a combination of INNOVATIVE HEARTH PRODUCTS war- unburned fuel (carbon and hydrogen) and ranty obligations for the PureFire Emissions moisture in the form of water vapor. The cata- Control System are limited to the terms set lyst is a technology that provides secondary forth below.
  • Page 19: Parts

    PARTS WOOD BURNING FIREPLACE MODELS WRE3836WS, WRE3836WH, WRE3836RS AND WRE3836RH 37/38 www.SuperiorFireplaces.US.com 127023-01A...
  • Page 20 PARTS WOOD BURNING FIREPLACE MODELS WRE3836WS, WRE3836WH, WRE3836RS AND WRE3836RH This list contains replaceable parts used in your fireplace. When ordering parts, see Replace- ment Parts on page 21 of this manual. NO. PART NO. DESCRIPTION QTY. Insulation Pan Fireplace Top...
  • Page 21 PARTS WOOD BURNING FIREPLACE MODELS WRE3836WS, WRE3836WH, WRE3836RS AND WRE3836RH This list contains replaceable parts used in your fireplace. When ordering parts, see Replace- ment Parts on page 21 of this manual. Right Side Rear Bottom Front Bottom Left Side REFRACTORY BRICK NO.
  • Page 22: Replacement Parts

    TECHNICAL SERVICE You may have further questions about instal- You can also visit our web site at lation, operation, or troubleshooting. If so, www.IHP.US.com. contact INNOVATIVE HEARTH PRODUCTS at 1-800-655-2008. When calling please have your model and serial numbers of your heater ready.
  • Page 23: Accessories

    ACCESSORIES Continued STORM COLLAR SC1-1 SQUARE TOP TERMINATION WITH LOUVERS ET-8DM, ET-8HT SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION ANTI-DRAFT SHIELD ETL-8DM, ETL-8HT (Round Top Termination Only) ADS-8DM MESH SQUARE TOP TERMINATION ETO-8DM MESH SQUARE TOP TERMINATION WITH SLIP SECTION ETLO-8DM OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION - AK4...
  • Page 24: Year Limited Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 25: Warranty

    WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.SuperiorFireplaces.US.com 127023-01A...
  • Page 26 IMPORTANT NOTICE Canadian code CAN/ULC-S610-M87 and NOTICE: The firebox canopy (hood) A manufactured shroud which other pertinent codes require stainless steel must not be modified or replaced with chimney for the installation of this fireplace. has been approved by a national a canopy that may be provided with A Cold Air Climate Kit is also required in the unvented decorative room heater.
  • Page 27 NOTES www.SuperiorFireplaces.US.com 127023-01A...
  • Page 28 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 127023-01 1-800-655-2008 Rev. A www.IHP.US.com 01/14 P127023-01...

This manual is also suitable for:

Wre3836whWre3836rhWre3836rs

Table of Contents