INDOOR UNIT INSTALLATION

INSTALLATION INSTRUCTIONS – INDOOR UNIT
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the
label on the product box to make sure that the
model number of the indoor unit matches the
model number of the outdoor unit.
STEP 1: SELECT INSTALLATION LOCATION
Before installing the indoor unit, you must choose
an appropriate location. The following are standards
that will help you choose an appropriate location
for the unit.
PROPER INSTALLATION LOCATIONS MEET
THE FOLLOWING STANDARDS:
• Good air circulation.
• Convenient drainage.
• Noise from the unit will not disturb other people.
• Firm and solid—the location will not vibrate.
• Strong enough to support the weight of the unit.
• A location at least 1m/40" from all other
electrical devices (e.g., TV, radio, computer).
If there is no fixed refrigerant piping, while choosing a location, be aware that you
should leave ample room for a wall hole (see Drill wall hole for connective piping step) for the
signal cable and refrigerant piping that connect the indoor and outdoor units. The default position
for all piping is the right side of the indoor unit (while facing the unit). However, the unit can
accommodate piping to both the left and right.
DO NOT INSTALL UNIT IN THE FOLLOWING
LOCATIONS:
• Near any source of heat, steam, or combustible gas.
• Near flammable items such as curtains or clothing.
• Near any obstacle that might block air circulation.
• Near the doorway.
• In a location subject to direct sunlight.
NOTE: ABOUT WALL HOLE
9