For this transmission the following protocol is used:
ARE H9
<STX> <ETX>
<STX> < transponder data > <ETX>
If transponder ID was read the following is displayed:
Does the host not answering to the <STX> <ETX> protocol of the ARE H9, then the ARE H9
will cyclic transmitting the <STX> <ETX> protocol until an answer of the host would be
received. During this the following display appears:
The user can cancel this waiting for a response of the host by pressing both arrow buttons, but
in this case the transponder ID will not transmitted.
5.4.4 Database/USB or Database/BT
In the database mode it is not able to read a transponder. It is intended to transmit and receive
record sets of the ARE H9 internal database to a host device as a PC, PDA, etc.
To exchange data in the database mode a software called reader-terminal included with the
ARE H9.
The usage of this software and the communication protocol is explained in an extra document
included with the software.
The database mode could be terminated by pressing both arrow buttons simultaneously, or by
initiating it by the PC-communication
During the Database/PC mode the ARE h9 will not switch off automatically.
---------------------------------------------------------------15/36-------------------------------------------------------------
->
<-
->
<-
999 000000000000
transmitting...
Await Connection
Abort ?
*)
mode.
Communic. Active
Abort ?
Host (PC, PDA, etc.)
<STX> <ACK> <ETX>
<STX> <ACK> <ETX>
*)
only with optional Bluetooth module
**)
database/ser. for Rs232 version