Installing And Operating The Pb16 Actuator - Martek Chicken Switch Instruction Manual

Pushbutton actuator
Table of Contents

Advertisement

 
 
4.2
Installing and Operating the PB-16 Actuator
STEP 1 – Be sure the magnet is in the OFF position.
STEP 2 – Determine which slots that the plunger should be in for your application and
adjust plunger to those slots. Also, determine the starting height of the plunger and
tightened the thumbscrews.
Generally, if you have a button that extends from your switchgear door, you will need to
slide the plunger to be closer to the 1.40" height so that it can clear the button. If you
have a recessed button, you may find that the lower setting of 0.30" works best as it
allows the most stroke below the switchgear surface. See Section 4.1 for more
information on mounting dimensions and adjustability.
The actuator can be positioned in one of the 
two sets of slots to best align the plunger 
over your button. 
 
 
 
© MarTek Limited.  All rights reserved. 
PB16 Operating Manual 
PB16‐033117 v0 
Position the actuator within the 
slots to best align the plunger 
height to your button and 
tighten the thumbscrews. 