OUTDOOR AREAS SAFTY APPLIANCE LOCATIONS
APPENDIX
This appliance is for outdoor and non-residential indoor use only.
This appliance must not be installed or used in residential indoor areas.
This appliance shall only be used in an above ground open-air situation with natural ventilation, without stagnant areas,
where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall comply with one of the following:
1. An enclosure with walls on all sides, but at least one permanent opening at ground level.
2. Within a partial enclosure that includes an overhead cover and no more than two walls.
3. Within a partial enclosure that includes an overhead cover and more that two walls, the following shall apply:
- At least 25% of the total wall area is completely open.
- At least 30% of the remaining wall area is open and unrestricted.
- In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted.
The following diagrams are examples of outdoor areas.
These same principles apply to any other shaped area.