Manual EasyMax LTC Self-Monitoring Blood Glucose System This Manual is intended for facilities where point-of-care testing is conducted by a healthcare professional. Please thoroughly read the EasyMax LTC Owner’s Guide and all product instructions before making use of this Manual.
Page 2
EasyMax LTC Self-Monitoring Blood Glucose System Manufactured by: EPS Bio Technology Corp. No.8, R&D Road III, Hsinchu Science Park Hsinchu, Taiwan 30077 Customer Service: 1-866-994-3345 (Toll Free) (Mon-Fri 8:00 AM - 6:00 PM)
Page 3
The EasyMax LTC Self-Monitoring Blood Glucose Test System is intended for the quantitative measurement of glucose in fresh capillary whole blood samples drawn from the fingertips, palm or forearm. Testing is done outside the body (In Vitro diagnostic use). The EasyMax LTC Blood Glucose System can be used by a single patient or for multiple-patient use in professional healthcare settings, as an aid to monitor the effectiveness of diabetes control.
Page 4
Based on this chart, many of these substances do not have an effect on EasyMax LTC blood glucose results. Blood Concentration, mg/dL Exogenous Therapeutic Suggestion tested Result EPS tested Interferent Conc. conc. by EPA (+/-) conc. Acetaminophen 0.5-3 Ascorbic Acid 0.8~1.2...
Page 5
2. Hematocrit below 20% may cause higher results. Hematocrit above 60% may cause lower results. EasyMax LTC System Specifications Brand Name EasyMax LTC Blood Glucose Meter Range 20-600 mg/dL Test Time 5 Seconds Memory Sets 480 Test Results Temp.
Page 6
Cleaning and Disinfecting the EasyMax LTC Meter in LTC Settings Choosing a disinfectant According to Guideline for Disinfection and Sterilization in Healthcare Facilities in 2008, you should clean your glucose meter after every use to prevent any possibility of cross infection. Wipes used should be EPA-registered as a disinfectant. Many EPA-registered disinfectant wipes have “2-minute” claims. If your wipes have higher or lower kill times, you should adjust your technique accordingly.
Page 7
The EasyMax LTC Blood Glucose Meter Overview of Display Meaning Date Shows the date Time Shows the time Apply Blood Test your level of blood glucose Test Result/Error Shows the test result or error Message message Insert a test strip to start testing...
Page 8
Setting the Time, Date and Medical Record - First Time Use Setting the current time and date on your meter is important if you use the meter memory. 1. Press (Power Button) 2. Press (Right Button) for 3. The screen display flashes the and hold the button until 2 seconds to get into the last 2-digits of the year.
Page 9
Running a Control Solution Test with EasyMax 15 Control Solution You need the meter, a test strip, and control solution 1. Put a test strip into the meter 2. Press (Left Button) to 3. Place the meter on a flat in the direction of the arrow. select the mode of surface, like a table.
9. Close the control solution vial tightly. Wipe the tip of the control cap with a tissue to remove any excess solution. Expiration date. This date applies to unopened bottles only. Once opened, the control solution has a shelf life of 90 days. Understanding Control Solution Test Results Important: Please follow your institution’s control solution testing regulations and procedures.
Page 11
Performing a Blood Glucose Test with EasyMax 15 Test Strips Please adhere to your institution’s medical device handling and site preparation procedures. In a Long Term Care facility setting, we recommend that a safety lancet be used for each individual glucose test.
Page 12
Troubleshooting Screen Messages Please do not make treatment decisions based on an error message. If you have any concerns, please contact Customer Service Toll-Free: 1-866-994-3345 (Eastern Time, Mon-Fri 8:00 am - 6:00 pm). Problem with the Humidified/Used strips Low Power System Action: Replace with Action: Replace with a Action: Replace the...
Page 13
EasyMax LTC Self-Monitoring Blood Glucose System Training Information Healthcare Professionals Page 11...
Page 14
Locates the electrode end of test strip Identifies the designated “hand hold” area 4. Demonstrates proper test strip use Only uses EasyMax LTC blood glucose meters with EasyMax 15 blood glucose test strips Runs a control solution test every time a new vial of test strips are opened Keeps test strips in their original vial...
Page 15
5. Demonstration of blood glucose testing. Demonstrates proper safety lancet technique when collecting blood sample Demonstrates appropriate disposal of safety lancets in accordance with institution’s policy Demonstrates the correct way to insert the test strip into meter Understands symbols that appear on the meter screen and what, if any, corresponding action Demonstrates correct placement of blood on test strip Records results as specified per your institution...
Page 16
EasyMax LTC Quiz This quiz is multiple choice, fill in the blank, and true/false. 1. The EasyMax LTC system does not require calibration. True False 2. EasyMax 15 control solution, once opened and assuming the expiration on the vial has not expired first, has an expiration date of: A. 60 days B. 6 months C. 3 months D.
Page 17
8. Describe the proper way to clean and disinfect the EasyMax LTC meter. 9. Describe how test strips should be inserted into the meter. 10. If you get this message, the blood glucose result is lower than _________ mg/dL. 11. What type of battery does the EasyMax LTC require? A.
Page 18
EasyMax LTC Blood Glucose Quality Control Results Log Facility Name: Monitor # Month/Year: Results Reviewed by: Date Time Staff Test Strip Level 1 Control Level 2 Control Action Taken Performing Lot# Lot Range Result Lot Range Result Page 16...