  • Page 1 EasyPlus mini MasterDriver Self-Monitoring Blood Glucose System Quick Reference Guide...
  • Page 2: Installing Batteries

    Installing Batteries 1. Open the battery door of the meter by sliping the tab in the direction of the arrow. 2. Insert a battery and the meter beeps. 3. Put the battery door back in place and snap it closed. The meter turns on automatically.
  • Page 3: Setting The Time And Date-First Time Use

    Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you intend to use the meter memory or if you want to download your results to a computer. 1. Press to turn the meter on and you will hear beeps.
  • Page 4: Running A Control Solution Test

    Running A Control Solution Test You need the meter, a test strip, and control solution. 1. Put a test strip into the meter in the direction of the arrow. 2. The meter beeps and turns on automatically. The icon shows itself. 3.
  • Page 5 5. Squeeze the bottle until a tiny drop forms at the tip of the bottle. 6. Touch the drop to the Blood collection area at the tip of the test strip. When you hear beeps, you have enough control solution in the test strip. 7.
  • Page 6: Inserting A Lancet Into The Lancing Device

    Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Unscrew the Cap. 2. Insert the lancet into the lancing device firmly then twist off the protective cover.
  • Page 7 3. Recap the front cap. 4. Select the desired penetration depth. Select 1-2 for soft or thin skin. 3 for average. 4-5 for thick or calloused skin.
  • Page 8 5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do not prick your finger until your meter and strip are prepared. 6. Set the lancing device aside until later in the test.
  • Page 9: Running A Blood Glucose Test With Blood From Your Fingertip

    Running A Blood Glucose Test With Blood From Your Fingertip 1. Wash your hands with soap and warm water. Rinse and dry thoroughly. Put a test strip into the meter in the direction of the arrow. The meter beeps and turns on automatically. 3.
  • Page 10 5. Gently squeeze and/or massage your fingertip until a round drop of blood on your fingertip 6. Touch the blood drop at the tip of the transparent window of the test strip. Do not put blood on top of the strip. When you hear beeps, you have enough control solution in the test strip.
  • Page 11: Running A Blood Glucose Test With Blood From Your Forearm

    Running A Blood Glucose Test With Blood From Your Forearm Please use the clear cap with the lancing device for AST testing. 1.This graphic shows where the meter cleared for alternative site testing. 2. Massage the puncture area of forearm or plam for a few seconds.
  • Page 12 4.If you choose the plam, repeat step 1-3 to obtain a drop of blood sample. 5.Press the trigger button to activate the lancing device. 6. Hold the device against forearm or palm and increase pressure until the blood sample size is sufficient.
  • Page 13: Discarding Used Lancets

    Discarding Used Lancets 1. Unscrew and remove the adjustable 2. Discard the used disposable lancet cap. Without touching the used lancet, into an appropriate sharps or stick the lancet tip into its protective biohazard container. cover. Grip the lancet carrier firmly and pull the lancet safely out.
  • Page 14: Viewing & Deleting Test Results

    Viewing & Deleting Test Results 1. Press to turn the meter on. 2. Press to enter memory mode. The meter shows the total number of the stored results first and then shows the latest result. Press to view the test result from latest to oldest.
  • Page 15 4. To delete a test result, press for 3 seconds. When display shows "dEL", press to confirm the deletion. Or press to cancel the deletion and go back to the total number of the stored results. 5. Press for 1 second to go back to the total number of the stored results.
  • Page 16: Screen Messages And Troubleshooting

    Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, please contact your local dealer. What it means ? What to do ? Humidified or used strip. Please replace with a new strip. Low power.
  • Page 17 What it means ? What to do ? You may have a very Please test again and if high blood glucose you get the same result, level(severe please contact your hypoglycemia), over 600 healthcare professional mg/dL. immediately. You may have a very low Please test again and if blood glucose you get the same result,...
  • Page 18: Running With Your Computer

    Running With Your Computer 1. Plug the EasyPlus mini MasterDriver Meter into a USB port on your PC. Windows will show menu automatically. 2. The display shows ”PC” and the GlucoManager Software runs automatically. More information in GlucoManager Software User’s Manual.