Do you have a question about the EasyMax V and is the answer not in the manual?
Questions and answers
steven
March 14, 2025
turn off voice
1 comments:
Mr. Anderson
May 14, 2025
To turn off the voice on the EPS Bio Technology EasyMax V, adjust the volume to mute mode. Press the Left Button to adjust the volume and press the Right Button to confirm the setting. The volume can be set from mute mode to 3 levels.
Intended Use The EasyMax V Self Monitoring Blood Glucose Test System is intended for the quantitative measurement of glucose in fresh capillary whole blood samples drawn from the fingertips or forearm. Testing is done outside the body (In Vitro diagnostic use). It is indicated for use at home (over the counter [OTC]) by persons with diabetes, or in clinical settings by healthcare professionals, as an aid to monitor the effectiveness of diabetes control.
Installing Batteries 1. Open the battery door on 3. Put the battery door back 2 Insert two batteries. You the back of the meter by in place and snap it closed. will hear opening music. pushing the tab in the direction of the arrow and pulling the door up.
Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you intend to use the meter memory. 1. Press to turn the meter on. 2. The last 2-digit of the year 3.
Setting The Language and Volume—First Time Use 3. Repeat step 1 and 2 to 1. Press to adjust the 2. And press to confirm set the volume. language.(En= English, the setting. Es = Spanish) Note: 1. The priority language of the blood glucose meter is set in English. 2.
Running A Control Solution Test You need the meter, a test strip, and control solution. 1. Put a test strip into the meter in 2. The meter turns on Place the meter on a flat the direction of the arrow. automatically and the surface, like a table.
Page 8
6. Touch the drop at the tip of the The meter starts to count 9. Remove the test strip test strip. down from 5 seconds and and throw it away after you then shows the result. have compared the reading 8.
Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Unscrew the Cap. 2. Insert the lancet into the lancing device firmly then twist off the protective cover.
Page 10
4. Select the desired penetration depth. 3. Recap the front cap. Note: Select 1-2 for soft or thin skin. 3 for average. 4-5 for thick or calloused skin.
Page 11
5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do not prick your finger until your meter and strip are prepared. 6. Set the lancing device aside until later in the test.
Running A Blood Glucose Test With Blood From Your Fingertip 1. Wash your hands with soap Put a test strip into the meter 4. Using the lancing device. and warm water. in the direction of the arrow. Hold the lancing device Rinse and dry thoroughly.
Page 13
6. Touch the blood drop at the tip 5. Gently squeeze and/or massage 7. The meter starts to count of the transparent window of your fingertip until a round drop down from 5 seconds and the test strip. Do not put blood shows the result.
Running A Blood Glucose Test With Blood From Your Forearm Please use the clear cap with the lancing device for AST testing. 1. Massage the puncture area 2. Press and hold the device 3. Press the trigger button to of forearm for a few with clear adjustable tip activate the lancing device.
Discarding Used Lancets 2. Please discard used disposable lancets 1. Unscrew and remove the adjustable cap. according to the recommendations of your Without touching the used lancet, stick the healthcare professional. lancet tip into its protective cover. Grip the lancet carrier firmly and pull the lancet safely out.
Page 16
Viewing & Deleting Test Results The meter provides 7, 14, 30, 60 and 90 days averaging to help track your blood glucose trend soundlessly. Press the to view the last 4. To delete a test result, press 1. Press until turning the test result.
Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, please contact your local dealer. Low power Humidified/Used strips System fault Action: Replace with new Action: Replace with a new Action: Replace the batteries first. batteries.
Page 18
System fault Test result is higher than The test result is lower than Action: Replace the 600 mg/dL. 20 mg/dL. batteries first. If Err appears Action: Test again. If the result Action: Test again. If the result again, please call Customer is still the same, try a control is still the same, try a control Service toll-free...
Page 19
The ”LF” and thermometer icon The ”HF” and thermometer icon appears. Temperature is too low, appears. Temperature is too high, outside the required range of outside the required range of 50°F - 104°F (10°C - 40°C). 50°F - 104°F (10°C - 40°C). Action: Relocate the meter to a Action: Relocate the meter to a location with temperature between...
Page 20
Manufacturer: EPS BIO TECHNOLOGY CORP. 2F, No.49-2, Lane 2, Guang-Fu Rd., Sec. 2, Hsinchu City, Taiwan 300 TEL:+886-3-5752522 FAX:+886-3-5752552 E-mail:info@epsbio.com.tw Website:http://www.epsbio.com EPS Customer Service Call:866-994-3345 Eastern Time:Mon. - Fri. 9:00 AM-5:00 PM During non-service hours, please contact your healthcare provider.
Need help?
Do you have a question about the EasyMax V and is the answer not in the manual?
Questions and answers
turn off voice
To turn off the voice on the EPS Bio Technology EasyMax V, adjust the volume to mute mode. Press the Left Button to adjust the volume and press the Right Button to confirm the setting. The volume can be set from mute mode to 3 levels.
This answer is automatically generated