Provision For Ventilation - Kenwood KS101G Series Instructions For Use Manual

Built-in gas oven with electric grill
Table of Contents

Advertisement

Provision for Ventilation

The appliance should be installed into a room or space with an air supply in
accordance with BS 5440-2: 2000.
For rooms with a volume of less than 5m
will be required.
For rooms with a volume of between 5m
free area will be required unless the room has a door which opens directly to the
outside air in which case no permanent ventilation is required.
For rooms with a volume greater than 10m
Note: Regardless of room size, all rooms containing the appliance must have direct
access to the outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2:
2000 should be consulted to determine the correct amount of free area ventilation
requirements.
The above requirements allow also for use of a gas oven and grill but if there are other
gas burning appliances in the same room, consult a qualified engineer.
26
- permanent ventilation of 100cm
3
and 10m
a permanent ventilation of 50cm
3
3
- no permanent ventilation is required.
3
free area