Current Output 4; Galvanically Isolated Pulse Output - Beko METPOINT Installation And Operating Manual

Thermal flow meter
Table of Contents

Advertisement

Installation and operating manual
4.3.2. Current output 4 ... 20 mA, 3-wire
Connection by means of plug-type connector A.
Connection diagram for METPOINT
q
Pin assignment - sensor
PIN-1
+ U
V
PIN-5
+ I
OUT
PIN-3
- U
V
PIN-2
PIN-4

4.3.3. Galvanically isolated pulse output

Connection by means of plug-type connector B.
Connection diagram for METPOINT
Pin assignment - sensor
PIN-1
+ U
V
PIN-4
Pulse
PIN-5
Pulse
PIN-3
- U
V
PIN-2
24
SF53 and METPOINT
®
1
+ U
V
V
5
+ I
OUT
3
- U
V
I
2
4 ... 20 mA
Function
Plus (+) connection, power supply
Current output
Minus (-) connection, power supply
not assigned
not assigned
®
SF53 and METPOINT
+
1
U
V
q
V
4
5
-
3
U
Impuls
V
Function
Plus (+) connection, power supply
Minus (-) connection, power supply
not assigned
BDL
®
BROWN
GREY
BLUE
®
BDL
BROWN
+
U
V
BLACK
GREY
BLUE
-
U
V
R = 4,7kΩ
Pulse
Pulse
1
2
3
4
5
6
7
8
9
Wire colour
Pin assignment - BDL
brown
PIN-7
grey
PIN-4
blue
PIN-8
white
black
1
2
3
4
5
R
6
7
8
9
Wire colour
Pin assignment - BDL
brown
black
PIN-4
grey
PIN-7
blue
white
EN
+ U
V
Analog IN (+)
- U
V
Analog IN (+)
+ U
V
METPOINT
SF53
®

Advertisement

Table of Contents
loading

Table of Contents