Appendix; Annexe - Ebro TFN 520 Manual

Hide thumbs Also See for TFN 520:
Table of Contents

Advertisement

English

Appendix

I Accuracy of probe
Categories of permitted tolerances con-
cerning pairs according to DIN IEC 584-2:
TC
Category Constant
value
K
1
± 1,5 ° C
2
± 2,5 ° C
3
± 2,5 ° C
J
1
± 1,5 ° C
2
± 2,5 ° C
T
1
± 0,5 ° C
2
± 1,0 ° C
3
± 1,0 ° C
E
1
± 1,5 ° C
2
± 2,5 ° C
3
± 2,5 ° C
Always apply the higher value of them.
NOTE: The system accuracy (probe +
device) results from the addition of the
single accuracies (system accuracy = accu-
racy device + accuracy probe).
06/2015 ba80010def02_TFN520-530
Value based
temperature
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,015 x T ° C
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,015 x T ° C
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,015 x T ° C
Français

Annexe

I Précision de la sonde Classes des tolé-
rances admises pour les thermocouples
selon la norme DIN IEC 584-2 :
TC
Classe
Valeur
constante
K
1
± 1,5 ° C
2
± 2,5 ° C
3
± 2,5 ° C
J
1
± 1,5 ° C
2
± 2,5 ° C
T
1
± 0,5 ° C
2
± 1,0 ° C
3
± 1,0 ° C
E
1
± 1,5 ° C
2
± 2,5 ° C
3
± 2,5 ° C
La valeur la plus haute doit être utilisée
dans tous les cas.
REMARQUE: L'exactitude du système (cap-
teur + appareil) dérive de l'addition des
exactitudes uniques (exactitude du sys-
tème = exactitude de l'appareil + exacti-
tude du capteur).
Valeur liée à la
température
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,015 x T ° C
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,015 x T ° C
± 0,004 x T ° C
± 0,0075 x T ° C
± 0,015 x T ° C
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tfn 530

Table of Contents