General IntelliFlo
Problem
Inadequate circulation.
(For IntelliFlo
alert display
®
messages, refer to Alerts and
Warnings on page 37).
Electrical problem.
(For IntelliFlo
alert display
®
messages, refer to Alerts and
Warning on page 37).
Mechanical Troubles and
Noise.
IntelliFlo
does not respond
®
to IntelliPool, IntelliComm
commands.
Troubleshooting Problems (Continued)
®
Possible Cause
Filter or pump basket dirty.
Suction/discharge piping is too small.
Speed is set too slow for proper filtration cycle.
Could appear as a "Low Voltage" alarm.
PRIME ERROR may be displayed.
Could appear as "Over Heat" alert.
PRIME ERROR may be displayed.
The pump motor is running but with loud noise.
Foreign matter (gravel, metal, etc.) in pump impeller.
Cavitation.
Improper automation IntelliFlo setup.
Communication network inoperative.
Corrective Action
Check trap basket; if plugged, turn pump off and
clean basket.
Check and clean pool filter.
Increase piping size.
Increase filtration run time
Check voltage at motor terminals and at panel while
pump is running. If low, see wiring instructions or
consult power company.
Check for loose connections.
Check line voltage; if less than 90% or more than
110% of rated voltage consult a licensed electrician.
Increase ventilation.
Reduce ambient temperature.
Tighten any loose wiring connections.
Motor internal terminal overload protector is open.
Motor runs too hot. Turn power to motor off.
Check for proper voltage.
Check for proper impeller or impeller rubbing.
If suction and discharge piping are not adequately
supported, pump assembly will be strained. Do not
mount pump on a wooden platform!
Securely mount on concrete platform for quietest
performance.
Disassemble pump, clean impeller, follow pump
service instructions for reassembly.
Improve suction conditions.
Increase pipe size.
Decrease number of fittings.
Increase discharge pressure.
1. Ensure that the communication cable is connected
at both ends.
2. Check that the IntelliFlo local address is set to "1".
3. Ensure that the IntelliFlo display says "DISPLAY
NOT ACTIVE", in case of IntelliPool.
A defective device on the network can inhibit the
proper operation of other network device. Devices
should be disconnected sequentially until the network
starts working.