Yanmar 2TNV70 Service Manual page 259

Industrial engines
Hide thumbs Also See for 2TNV70:
Table of Contents

Advertisement

Troubleshooting Charts
Trouble Symptom
Starting Problem
Cause
Clogged Air Filter
Engine Used at High Temperatures or at
High Altitude
Clogged Exhaust Pipe
Starting Motor Defect
O
Alternator Defect
O
Open-Circuit in Wiring
O
Battery Voltage Drop
O
TNV IDI Service Manual
Poor
Insufficient
Exhaus
Engine
t
Output
Color
Engine
Starts
Exhaust
During
but Stops
Color
Work
Soon.
Exhaust
Smoke
O
O
O
O
O
O
O
Engine
Engine Oil
Surging
O
O
O
Engine
Air
Coolant
Intake
Corrective Action
O
Clean Air Filter.
Study Output Drop and Load
O
O
Matching.
O
Clean Exhaust Pipe.
Repair or Replace Stater Motor.
Repair or Replace Alternator.
Repair Open Circuit.
Inspect and Change the Battery.
TROUBLESHOOTING
Reference Pages
See "Clean Air Cleaner Element"
on page 5-16.
See "Starter Motor" on page 10-8.
See "Removal of Alternator" on
page 11-10. or Removal of
Dynamo on page 11-18
See "Check Battery" on
page 5-12.
13-17