ABB NextMove e100 Quick Installation Manual page 48

Hide thumbs Also See for NextMove e100:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
48 Snabbinstallationshandbok – NextMove e100
Serieport
Signal
Bit rates
Ethernet-kommunikation
Description
Signal
Protocols
Bit rates
CAN-kommunikation
Description
Signal
Channels
Protocol
Bit rates
Miljövillkor
Description
Operating temperature range
Maximum humidity
Maximum installation altitude
(above m.s.l.)
Shock
Vibration
Unit
RS232 or RS485/422 non-isolated
baud
9600, 19200, 38400,
57600 (default), 115200
Unit
2 twisted pairs, magnetically isolated
Ethernet POWERLINK & TCP/IP
Mbit/s
Unit
Kbit/s
10, 20, 50, 100, 125, 250, 500, 1000
Unit
Min
°C
0
°F
+32
%
80% for temperatures up to 31 °C (87 °F)
decreasingly linearly to 50% relative
humidity at 45 °C (113 °F),
m
ft
IEC 60068-2-6/27 or equivalent
1 G, 10-150 Hz according to
IEC 60068-2-6/27 or equivalent
All models
Value
100
Value
2-wire, isolated
1
CANopen
Max
+45
+113
non-condensing
2000
6560
10 G according to

Advertisement

Table of Contents
loading

Table of Contents