Proceed as follows:
1. Open the handle of the thermometer and set the DIL switch 9 to OFF (SLAVE).
2. Switch on the thermometer using the measurement button.
3. Press the Setup key. The following scrolling message appears on the display -
"Bluetooth on-up, off-down". Activate the Bluetooth operation by pressing the Up
key below the display. A blinking icon in the display indicates the stand-by mode
of the Bluetooth module - The lock icon indicates continuous operation.
Note: If the auto-executing battery test detects that the battery is too low (display:
„LowBat - no BT"), the Bluetooth application is not started.
4. Now launch the Bluetooth software on your computer and let it search for Bluetooth
devices and connect them. (The exact functioning for your Bluetooth application
can be referred to from the corresponding operating manual).
5. The thermometer is detected as „IR Therm....". The requested PIN is „1234" by
default. Right-click the icon of the device and switch to the „Properties" sub-
menu. Remember the number of the ComPort. The green light-emitting diode over
the display of the thermometer indicates the existing connection.
6. Now start the corresponding application software, if yet to start, for the thermometer.
Before you can exchange data between the thermometer and the computer you
have to set the ComPort number as mentioned in point 5.
7. Press the Setup key and then the Down key below the display to terminate the
Bluetooth™ connection. If data is being transferred at this moment, you cannot stop
the Bluetooth™ module.
Important note: Aforementioned statements are applicable only to the thermometer in
the delivery condition. It can be set by the user using the „BlueTool" software. Refer to
the „User-defined configuration" section for this purpose.
8.7.2 Master mode (active mode/Bluetooth™)
After switching on, the thermometer is automatically connected to the computer, the
address of which has been programmed in the thermometer. This takes place using
the supplied BlueTool software (refer to the „User-defined configuration" section for
this purpose). The active mode is especially suitable for the intermittent operation of
the infrared thermometer. Energy consumption of the thermometer is considerably less
than that in the passive mode.
Proceed as follows:
1. Open the handle of the thermometer and set the DIL switch 9 to ON (Master).
2. Switch on the thermometer using the measurement button.
3. Press the Setup key, the following scrolling message appears on the display -
"Bluetooth on-up, off-down".
Activate Bluetooth™ by pressing the Up key below the display. A blinking icon in the
display indicates the stand-by mode of the Bluetooth module - the lock icon indicates
continuous operation.