Victron energy MPPT 100/30 User Manual page 10

Bluesolar charge controllers
Hide thumbs Also See for MPPT 100/30:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
On all models with software version V 1.12 or higher a binary
LED code helps determining the position of the rotary switch.
After changing the position of the rotary switch, the LEDs will
blink during 4 seconds as follows:
Switch
LED
position
Bulk
0
1
2
3
4
5
6
7
Thereafter, normal indication resumes, as described below.
Remark: the blink function is enabled only when PV power is
present on the input of the controller.
3.6 LEDs
LED indication:
 permanent on
 blinking
 off
Regular operation
Bulk (*1)
Absorption
Automatic equalisation (*2)
Float
Note (*1): The bulk LED will blink briefly every 3 seconds when
the system is powered but there is insufficient power to start
charging.
Fault situations
Charger temperature too high
Charger over-current
Charger or PV over-voltage
Internal error (*3)
Note (*3): E.g. calibration and/or settings data lost, current sensor
issue.
8
LED
Abs
1
1
0
0
0
1
0
1
1
0
1
0
1
1
1
1
LEDs
Bulk
LEDs
Bulk
LED
Float
frequency
1
1
0
1
0
1
0
1
Absorption
Absorption
Blink
Fast
Slow
Slow
Slow
Slow
Slow
Slow
Slow
Float
Float

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mppt 100/50