Accuracy (cont'd)
Capacitance
Range
40.00 nF
400.0 nF
4.000 µF
40.00 µF
200.0 µF
Press REL before connecting test leads to capacitor.
This compensates for test lead capacitance.
Accuracies are for film capacitors (capacitors with negligible
dielectric absorption); measurements of larger capacitors
can take up to 10 seconds.
Temperature
Range
–20 °C ~ 0 °C
°C
0 °C ~ 400 °C
400 °C ~ 1000 °C
–4 °F ~ 32 °F
°F
32 °F ~ 752 °F
752 °F ~ 1832 °F
K-type thermocouple range and accuracy not included.
Thermocouple supplied with meter is rated –50 °C to 204 °C (–58 °F to 400 °F).
Accuracy is ±2.5 °C (4.5 °F) or 0.75% of reading, whichever is greater.
Accuracy specification assumes ambient temperature is between 18 °C and 28 °C
and is stable to ±1 °C. For ambient temperature changes of ±5 °C, rated accuracy
applies after 1 hour.
Accuracy
± (3.5% + 0.20 nF)
± (2.5% + 0.5 nF)
± (3.5% + 0.005 µF)
± (4.0% + 0.05 µF)
± (5.0% + 0.5 µF)
Accuracy
± (6.0% + 5 °C)
± (1.5% + 4 °C)
± (1.8% + 5 °C)
± (6.0% + 9 °F)
± (1.5% + 7.2 °F)
± (1.8% + 9 °F)