2 . Accessories & prepare on site
R/C main unit, wood screw (ø3.5 x 16) 2 pcs
Accessories
User's Manual, Installation Manual
Parts procured at site
Item name
Switch box
For 1 piece or 2 pieces (JIS C 8340 or
equivalent)
Thin wall steel pipe for electric appliance
(JIS C 8305 or equivalent)
Lock nut, bushing (JIS C 8330 or equivalent) As required
Lacing (JIS C 8425 or equivalent)
Putty
Molly anchor
2
R/C cable (0.3 mm
x 2 pcs)

3. Remote control installation procedure

Determine where to install the remote control

Installation
"Using a switch box"
"Installed directly on a wall"
Wiring direction "Backward"
"Upper center", "Upper left"
Cautions for selecting installation place
(1) Installation surface must be flat and sufficiently strong.
R/C case must not be deformed.
(2) Where the R/C can detect room temperatures accurately.
This is a must when detecting room temperatures with
the temperature sensor of R/C.
· Install the R/C where it can detect the average tempera-
ture in the room.
· Install the R/C separated from a heat source sufficiently.
· Install the R/C where it will not be influenced by the
turbulence of air when the door is opened or closed.
Select a place where the R/C is not exposed to direct
sunlight or blown by winds from the air-conditioner or
temperatures on the wall surface will not deviate largely
from actual room temperature.
AMP Air Conditioning
Q'ty
Remark
1
These are not required when installing
directly on a wall.
As required
As required Necessary to run R/C cable on the wall.
Suitably For sealing gaps
As required
As required See right table when longer than 100 m
-
78
-
— 4 —
When the cable length is longer than
100 m, the max size for wires used
in the R/C case is 0.5 mm
them to wires of larger size near
the outside of R/C. When wires are
connected, take measures to prevent
water, etc. from entering inside.
< 200 m
< 300 m
< 400 m
< 600 m
Installation space
Wiring
30mm
R/C temperature sensor
Secure minimum spaces for
disassembling the case.
Upper left and Upper right sides
Bottom side...120mm or more
www.ampair.co.uk | sales@ampair.co.uk
'15 • PAC-T-236
2
. Connect
2
0.5 mm
x 2-core
2
0.75 mm
x 2-core
2
1.25 mm
x 2-core
2
2.0 mm
x 2-core
30mm
30mm
......30mm or more
If using L-shaped
screwdriver, 50mm or
more is available.