Note: Connection to personal computer
It can be set from a personal computer via the USB port (mini-B).
Connect after removing the cover for USB port of upper case.
Replace the cover after use.
If dust, insect, etc. enters, it could cause electric
shocks or breakdown.
Special software is necessary for the connection.
For details, view the web site or refer to the engineering data.
Do not connect to a personal computer
without using the special software.
Do not connect the personal computer to the USB
simultaneously with other USB devices.
It could cause malfunction or breakdown of R/C or
personal computer.
Note: Initializing of password
Administrator password (for daily setting items) and service password (for installation, test
run and maintenance) are used.
The administrator password at factory default is "0000". This setting can be changed
(Refer to User's Manual). When the administrator password is forgotten, it can be
initialized, if the [High power] and the [Energy-saving] buttons are pushed simultaneously
for 5 seconds on the administrator password input screen.
Service password is "9999", which cannot be changed.
When the administrator password is input, the service password is also accepted.
Note: Combination of R/C and indoor unit
(1) It can be used as the combination of Main and Sub with RC-E3 to -E5 type of wireless R/C (option part).
(2) It can be combined with FD-V or FD-KX E6 type and later types of indoor units
(3) In cases of combination with FD-V or FD-KX E6 type unit, there are some controlling items which cannot be used.
If operating such items, the message "Invalid request" is displayed.
AMP Air Conditioning
Cover
— 8 —
-
82
-
www.ampair.co.uk | sales@ampair.co.uk
'15 • PAC-T-236