Fujitsu B23Q8WD-G-01-J Hardware Manual page 23

Sparc enterprise servers for solaris operating system
Table of Contents

Advertisement

No.
CR ID
23
6522433
24
6527811
25
6530288
26
6532215
27
6534471
6718173
28
6473457
Description
Workaround
Due to problems in the CPU fault management software, incorrect information is written to the
fault report.
Check system status on XSCF.
This problem has been fixed by the following patch.
127127-11 or later SunOS 5.10: kernel patch
showhardconf(8) on XSCF can not display PCI card information that is installed in External I/O
Expansion Unit, if the External I/O Expansion Unit is configured using PCI hotplug. Also the PCI
card information is not displayed by Hardware Configuration Display of Machine Administrator
Software.
Apply the following patch.
128346-01 or later SunOS 5.10: pcihp patch.
Ap_Id format may not be shown correctly by cfgadm(1M).
Apply the following patch.
120011-14 or later SunOS 5.10: kernel patch
volfs or dscp service may fail when domain is booted.
svc:/platform/sun4u/dscp:default:Method "/lib/svc/method/svc-dscp start" failed with exit status 95.
svc:/system/filesystem/volfs:default: Method or service exit timed out. Killing contract 59.
Restart the service if the failure is observed. To avoid the problem, issue the following commands.
# svccfg -s dscp setprop start/timeout_seconds=count: 300
# svccfg -s volfs setprop start/timeout_seconds=count: 300
# svcadm refresh dscp
# svcadm refresh volfs
Domain may panic.
Add the following line to /etc/system and reboot the domain.
set heaplp_use_stlb=0
Though CR:6534471 has been resolved by the patch 125100-06 or later, CR: 6718173 hasn't been
resolved yet. Therefore, the above workaround is still required.
There is a note on using the standard Solaris fibre channel driver with the following host bus
adaptors.
Target Host Bus Adaptors
- XSEFC401AF
- XSEFC402AF
- XSEFC401AU
- XSEFC402AU
The cfgadm command fails with error messages when attempted to disconnect disk array device
from fibre channel switch connection.
Also, when a single path is disabled in multi-path (MPxIO) configuration, both paths might fail.
Apply the following patch.
125100-04 or later SunOS 5.10: Kernel Update patch
17