Opticon ESL Server Manual page 96

Electronic shelf label
Hide thumbs Also See for ESL Server:
Table of Contents

Advertisement

Supported ESL settings
The following list of SQL-commands is currently supported to change ESL settings. Valid commands
will be moved to the action_pending table. Disgarded settings and settings that match the current
setting will be moved to the action_results table.
ACTION
POLL_INTERVAL (int)
INSERT INTO `actions_staging`(`ACTION`, `MAC`, `PARAM1`) VALUES ('POLL_INTERVAL',
'3889DC000000A842', 20);
POLL_TIMEOUT (int)
INSERT INTO `actions_staging`(`ACTION`, `MAC`, `PARAM1`) VALUES ('POLL_TIMEOUT',
'3889DC000000A842', 20);
SCAN_INTERVAL
(int)
INSERT INTO `actions_staging`(`ACTION`, `MAC`, `PARAM1`) VALUES ('SCAN_INTERVAL',
'3889DC000000A842', 60);
DISPLAY_OPTIONS
(int)
INSERT INTO `actions_staging`(`ACTION`, `MAC`, `PARAM1`) VALUES ('DISPLAY_OPTIONS',
'3889DC000000A842', 1);
SCAN_CHANNELS
(flags)
INSERT INTO `actions_staging`(`ACTION`, `MAC`, `PARAM1`) VALUES ('SCAN_CHANNELS',
'3889DC000000A842', '101746688');
TEMPERATURE
INSERT INTO `actions_staging`(`ACTION`, `MAC`, `PARAM1`) VALUES ('TEMPERATURE',
'3889DC000000A842', 0);
MAC
PARAM1 (default; min; max)
MAC-Address (16) Min. poll interval in seconds (20, 5, 200)
MAC-Address (16) Poll timeout in polls (10, 5, 30)
MAC-Address (16) Associate interval in seconds (60, 60, 300)
MAC-Address (16) 0: normal, 1: upside down
MAC-Address (16) 11: 0x00000800
12: 0x00001000
13: 0x00002000
14: 0x00004000
15: 0x00008000
16: 0x00010000
17: 0x00020000
18: 0x00040000
(0x06108800 = 11, 15, 20, 25, 26)
MAC-Address (16) Temperature range. (0=default; 0, 4) (>0
values are to compensate for lower
temperatures, but shorten battery life)
96
Opticon ESL
ESL Server manual
19: 0x00080000
20: 0x00100000
21: 0x00200000
22: 0x00400000
23: 0x00800000
24: 0x01000000
25: 0x02000000
26: 0x04000000