3.
You can trigger the Timer mode by pressing the TIMER button when LCD
menu screen shows "Ready To Fog". Pressing TIMER button again ends the
Timer mode.
Note: There is a Non-Stop Burst function between Timer Out
1% and Timer Out 100%. Choosing this function can
make machine generate continuous fog output under
Timer mode.

Volume Output

1.
When the LCD menu screen displays "Ready To Fog", press FUNCTION
four time. The screen shows VOLUME OUT.
2.
Use the UP/DOWN buttons to adjust the fog output volume of the Volume
mode from 1% to 100%. Trigger the Volume mode by pressing the
VOLUME button when LCD menu screen shows "Ready To Fog". Pressing
the VOLUME button again ends the Volume mode.
Note: There is a Non-Stop Burst function between Volume Out
1% and Volume Out 100%. Choosing this function can
make machine generate continuous fog output under
Volume mode.

DMX Addressing

1.
When LCD menu screen displays "Ready To Fog", press FUNCTION five
times. The screen shows DMX 512 ADD.
2.
Use the UP/DOWN buttons to adjust the DMX address.

Manual Operation

Pressing the MANUAL button when LCD menu screen displays "Ready To Fog"
produces 100% full fog output. Release the MANUAL button to stop fogging.

DMX Control

The FQ-100 fog generator uses 1 channel on a standard DMX512 link to control
volume output. This channel has a value range of 0 to 255. Timer functions such
as duration and interval can be programmed using a DMX controller.
When the channel DMX value equals 0 to 5, the unit is OFF. The volume output
rises as the DMX value is increased from a minimum output at a DMX value = 6
approaching the maximum at a DMX value = 255 (100%).