vita Vacumat 4000 Premium Operating Manual

vita Vacumat 4000 Premium Operating Manual

Hide thumbs Also See for Vacumat 4000 Premium:
Table of Contents

Advertisement

VITA - Vacumat 4000
Premium
Operating - Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vacumat 4000 Premium and is the answer not in the manual?

Questions and answers

Morello angelo
July 8, 2025

Non carica più i programmi

Summary of Contents for vita Vacumat 4000 Premium

  • Page 1 VITA - Vacumat 4000 Premium Operating - Manual...
  • Page 2: Table Of Contents

    Storing program parameters ....................12 7.2.1 Copying programs......................12 7.2.2 Deleting the program ....................13 7.2.3 Changing to graphics mode ..................13 7.2.4 Changing to Operation On ................... 13 7.2.5 Program Start/Stop ...................... 13 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 3 Unit no. of furnace....................... 18 Software version ......................... 19 Hotline ..........................19 9.10 Temperature adjustment – checking with Silver Test Set........... 19 9.10.1 Silver Test Set VITA order no. B 230................19 9.11 Automatic temperature adjustment ..................20 9.12 Key signal..........................20 9.13 Storing firing data ........................
  • Page 4: Technical Information

    • program parameters can be altered for the course of one program run with the # key • the job number can be entered • tabular view of the current users' names 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 5: Utility Programs For

    1set of firing trays A + B 1 set of firing trays G 1 operating manual Vacuum pump optionally available: 230 Volts, 50/60 Hz or 100/110 Volts AC, 50/60 Hz weight approx. 6.4 kg 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 6: Installing The Furnace And Setting Up For Use

    Close the lift by pressing the lift key. To switch off the furnace, press the finish key and confirm with the yes key. When the message END appears, the furnace can be switched off at the mains switch. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 7: Safety Advice

    Other fuse types may not be used. (Abb.5, Pkt.1) (Abb.5, Pkt.2) 230 Volt: T 1 H 250 V T 8 H 250 V 100/110 Volt: T 3,15 H 250 V T 15 H 250 V 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 8: Ce Mark

    0% - 100% (100% = lift completely closed) (see also section on lift positions for pre-drying) 1 lift position for cooling 0% - 100% (see also section on lift positions for cooling) 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 9: Temperature Rise

    If during a firing program the vacuum level of 30% is not reached within 15 sec., the firing program is aborted and the error message Vacuum is shown on the display (see section on error messages). Return with key "Continue" (confirm) and 2 x Standby key. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 10: Main Menu

    During pressing the individual buttons repeated the following symbols will be written: Button # = store Button * = deleate Pressing buttons Number Space & Ä Â ç É Ö Ñ Ü 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 11: Activating / Ending Standby Menu

    VITA 08: 20 0 8.08.00 500 °C VITA O M EG A 9 00 V ITA TI TAN K ER AMIK VITA O M EG A V ITAD UR AL PHA VITAPR ESS VITAPR ESS A LP HA...
  • Page 12: Coding / Decoding User

    After cooling to 50 °C below the standby temperature, the pump is switched off, the lift moves into its upper position and the temperature rises to the standby temperature: 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 13: Entering Program - Tabular Mode

    Select required program with the up/down key • Press Copy key • Press up/down key to return to newly selected program • Insert program with Paste key • Save with OK key 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 14: Deleting The Program

    Press the Stop key, program is aborted. By means of utility program, it is possible to program the Stop key so that it is necessary to press the key twice to make the program abort. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 15: Program Entry - Graphics Mode

    The Table key can be pressed to change to tabular mode. Press the Stop key to abort the program. The Stop key can be programmed in the utility program so that the key must be pressed twice before the program is aborted. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 16: Entering / Altering Lift Positions For Pre-Drying

    Save by pressing OK key • End by pressing vacuum key The possible entry values appear in the display. 8.1.6 Deleting vacuum • Press vacuum key • Press * key – vacuum is now deleted. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 17: Selecting Slow Cooling

    Press key "job no." – field for job no. appears • Enter job no. (max. 6 digits) • Save with OK key 8.1.10 Selecting tabular view Press Table key – display shows tabular view. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 18: Utility Programs

    Store with OK key. • Selected speed will be shown by pressing button START • Return to service (utilities) menu by pressing service key or return to main menu by pressing main menu key. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 19: Signal Time

    Confirm with OK key. • Display shows unit no. of the furnace. • Return to service (utilities) menu by pressing service key • return to main menu by pressing main menu key. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 20: Software Version

    9.10 Temperature adjustment – checking with Silver Test Set With this program and the VITA Silver Test Set (VITA order no. B 230) the temperature in the firing chamber can be tested and readjusted in a temperature range of plus/minus 20°C. When carrying out a temperature adjustment it is essential to heed the instructions for the silver test (instructions given in the Silver Test Set).
  • Page 21: Automatic Temperature Adjustment

    Confirm with OK key. • Select with On/Off key. • Save with OK key. • Return to service (utilities) menu by pressing service key • return to main menu by pressing main menu key. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 22: Display Settings

    Attention: within these 5 seconds it is possible to abort the program by pressing the Stop key. • Return to service (utilities) menu by pressing service key • return to main menu by pressing main menu key. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 23: Program Parameters

    Select desired field with up/down key, enter day/month/year. • Confirm with OK key. • Return to service menu by pressing service key • return to main menu by pressing main menu key. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 24: Temperature Hold Program

    Smart Card. The programs can be stored in the memory of the furnace under the name of the user, stored, coded and used. (see section on coding user). Software updates can likewise be transferred from the Smart Card to the internal memory. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 25: Error Messages

    Lift out of order. • Lift blocked. • Power failure lasting more than 10 seconds. • Recover, power failure of less than 10 seconds. • Muffle or fuse out of order. • Program memory full. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 26: Firing Charts

    3.00 1.00 For many years now excellent results have been obtained with alloys in conjunction with VITA Metal Ceramics (OMEGA, OMEGA 900, VMK 95) when the thermal expansion coefficient of the alloy, measured in the range from 25°C – 600°C, corresponds to 14.0 – 14.4 x 10 .
  • Page 27 4.00 1.00 For many years now excellent results have been obtained with alloys in conjunction with VITA Metal Ceramics (OMEGA, OMEGA 900, VMK 95) when the thermal expansion coefficient of the alloy, measured in the range from 25°C – 600°C, corresponds to 14.0 – 14.4 x 10 .
  • Page 28 4.00 1.00 For many years now excellent results have been obtained with alloys in conjunction with VITA Metal Ceramics (OMEGA, OMEGA 900, VMK 95) when the thermal expansion coefficient of the alloy, measured in the range from 25°C – 600°C, corresponds to 14.0 – 14.4 x 10 .
  • Page 29 Pre-heat the restoration in the muffle pre-heating oven with flux but still without solder for 15-20 min. at 400 °C Program 94 End temperature is the operating temperature of the corresponding solder + 50 °C pre-drying 1.00 min. heating-up 3.00 min. hold time 4.00 min. 39/03/04 Vita Zahnfabrik H.Rauter GmbH&Co.KG 79704 Bad Säckingen...
  • Page 30 Service parameters Entering / altering program names Signal time Entering / altering program parameters 13, 15 Silver Test Set VITA order no. B 230 Entering / altering the program names Smart Card Entering job no soft keys Entering program – tabular mode...
  • Page 31 (culpa in contrahendo,breach fo contract, tort liability, etc.) can only be made in the case of intent or gross negligence. Date of issue of these instructions for use: 06/01. TÜV Rheinland VITA Zahnfabrik H. Rauter GmbH & Co. KG Postfach 1338 ⋅ D-79704 Bad Säckingen Tel. +49/(0)7761/562-0 ⋅ Fax +49/(0)7761/562-299 Hotline: Tel.

Table of Contents