Contents Preface Safety instructions Hazard levels Description in this service manual Service groups Functional group structure Textual description Technical Features Field of application Safety installations Type plate Parts of the system Front view AB Service group setup 010 Safety information 020 Overview 030 Function 040 Service activities...
Preface Good service work requires extensive and practice-orient- If you should require supplements, have corrections or ed training as well as well-structured training materials. questions regarding this document, please address these Hence we offer regular basic and advanced training pro- citing the following subject to: grammes covering the entire product range for all service international-service@de.kaercher.com...
Description in this service manual Service groups Example: Install/uninstall ANRA wheel axle Install/uninstall wheel axle Service group Component Activity Observe the allocation of service groups to the appliance components in the overview diagram in Chapter "Overview over the service and functional groups". Functional group structure Safety instructions Overview...
Parts of the system Front view 1 Power switch 2 Instrument panel 3 Intermediate ring 4 Sediment container 5 Suction head AB Service group setup 010 Safety information WARNING Switch off the appliance and remove the plug from the socket. Observe general safety information! 020 Overview ABIT Uninstall / install instrument panel...
1 Instrument panel 2 Hood Note Mind the wiring when removing the cover. Thread the instrument panel through the opening of the cover. Remove the hood. Installation information Upon reinstallation, make sure that no cables are jammed! ABIT Uninstall / install instrument panel 1 Screws 2 Instrument panel ...
AC Service group suction system 010 Safety information WARNING Switch off the appliance and remove the plug from the socket. Observe general safety information! 020 Overview ACTM Uninstall / install Tact magnets ACSK Uninstall / install suction head ACST Uninstall/ install suction turbine ACTE Uninstall / install Tact unit ACFF Uninstall / install flat fold filter 030 Function...
ACFF Uninstall / install flat fold filter 1 Handle 2 Locking 3 Cover filter Pull on the lock. Open the cover of the filter. 1 Flat fold filter Remove flat folded filter. ACTE Uninstall / install Tact unit ...
Page 14
1 Tact magnets 2 Tact unit Remove tact magnets. Remove tact unit. Opening / closing the Tact unit 1 Screwdriver 2 Locking nose 3 Casing cover Tact unit Detach the Tact unit from the latches using a screwdriv- ...
AH Service group 010 Safety information WARNING Switch off the appliance and remove the plug from the socket. Observe general safety information! 020 Overview AHFS Uninstall / install filling level sensor AHGA Uninstall / install power switch AHSE Uninstall / install control electronics 1 AHSF Uninstall / install control electronics 2 030 Function No special functional characteristics.
AHSF Uninstall / install control electronics 2 AHSE Uninstall / install control electronics 1 1 Screws 2 Control electronics 2 Disconnect all electrical connections. Unscrew the screws. Remove control electronics 2. Note Observe the connection diagram. 050 Maintenance and inspection Service group does not contain any maintenance and in- spection points.