Specifications - Extech Instruments 380941 User Manual

Ac/dc mini clamp meter
Table of Contents

Advertisement

Specifications

General Specifications
Display
Functions
Polarity
Current sensor
Overload indication
DCA zero adjust
Display rate
Battery
Operating temperature
Operating humidity
Power consumption
Sampling time
Weight
Dimensions
Jaw opening
Standards
Range Specifications
Function
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
3-3/4 (4032 count) Digit LCD with 40 segment bargraph
ACA, DCA, ACV, DCV, Resistance, Frequency, Continuity
"-" indicates negative polarity
Hall effect sensor type
OL
One touch zero key
3 readings/second (30 readings/second for bargraph)
Two 1.5V AA batteries
o
-10
C to 50
< 85% RH
Approximately 17mA DC
3 times/sec (display); 30 times/sec (bargraph)
225g (8 oz.) including battery
183 x 63.6 x 35.6mm (7.2 x 2.5 x 1.4") (HWD)
23mm (0.9")
IEC 1010 Category III 300V, Category II 600V
Range
Resolution.
40A
10mA
0 to 150A
100mA
150 to 200A
100mA
40A
10mA
0 to 150A
100mA
150 to 200A
100mA
400V
0.1V
400V
0.1V
40 to 400
0.1
1 to 100k
0.001-100
o
o
o
C (4
F to 122
F)
Accuracy
±(1.0% +2dgts)
±(1.0% +2dgts)
±(2.2% +2dgts)
50/60Hz
±(1.0% +3dgts)
±(1.0% +3dgts)
±(2.2% +3dgts)
±(1.0% +2dgts)
50/60Hz
±(1.5% +2dgts)
±(1.0% +2dgts)
±0.5% ±2dgts
5
Overload
protect
400A DC
400A DC
400A DC
40 to 400Hz
±(1.5% +4dgts)
400A AC
±(1.5% +4dgts)
400A AC
±(2.5% ±4dgts)
400A AC
1000VDC
40 to 400Hz
±(2.0% +4dgts)
800V AC
Beeper <approx
600V AC
38
Sensitivity;
600V AC
5VAC
380941A-EU-EN v1.0 2/14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 380941 and is the answer not in the manual?

Questions and answers

Table of Contents