SolaX Power ZDNY-TL series User Manual

SolaX Power ZDNY-TL series User Manual

Hide thumbs Also See for ZDNY-TL series:

Advertisement

Quick Links

.,
614.00010.04

Advertisement

loading
Need help?

Need help?

Do you have a question about the ZDNY-TL series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SolaX Power ZDNY-TL series

  • Page 1 614.00010.04...
  • Page 4 PV array Inverter Electrical grid Distribution Distribution...
  • Page 7 Earth Fault Alarm(Optional) SOLAX POWER...
  • Page 8 Adjustable displacement factor range 0.90 under-excited Operating ambient temperature range: -20°C...+60°C Ingress protection: IP54(Fans),IP65(Other) SolaX Power Co.,Ltd. Protective class: ADD:No.288 Shizhu Road, Tonglu Economic Development Zone, Dongxing District, Tonglu City, Zhejiang Province, China. Over voltage category: III (MAINS), II (PV) TEL: +86 571 5626 0011 E-mail: info@solaxpower.com...
  • Page 9 Copyright Declaration The copyright of this manual belongs to SolaX Power Co., Ltd. . Any corporation or individual should not plagiarize, partially copy or fully copy it (including software, etc.), and no reproduction or distribution of it in any form or by any means. All rights reserved.
  • Page 10 ZDNY No direct sunlight No rain exposure No snow lay up Direct sunlight Rain exposure Snow lay up...
  • Page 12 Input A Input B Input A Input B...
  • Page 13 Connection Rated connecting type capacity and rating Stripping length...
  • Page 15: Earth Connection

    Earth connection You can additionally earth the inverter enclosure of a second earthing or equipotential bonding is required locally. This prevents touch current if the original protective conductor fails. Cable size: 12AWG. Connection step: 1. Strip the earthing cable insulation. 2.
  • Page 16 step6 step8 step5...
  • Page 17 m Earth Fault Alarm(Optional) The earth fault alarm is the additional detection for functionally earthed PV arrays, as required by AS 4777.2 and AS/NZS 5033, is present in the inverter, this additional detection shall, before start-up of the system— (a) open circuit the functional earth connection to the PV array; (b) measure the resistance to earth of each conductor of the PV array;...
  • Page 19 ● The condition or the The inverter’s output value of PV input voltage of each phase Real-time power Daily energy ● ●...
  • Page 23 current...
  • Page 25 When the inverter or other related components need to be disposed. Have it carried out according to local waste handling regulations. Please be sure to deliver wasted inverters and packing materials to certain site, where can assist relevant department to dispose and recycle.