Download Print this page

Wilbur Curtis Company ThermoPro Twin Service Manual page 10

Advertisement

Cleaning the ThermoPro
Regular cleaning and preventive maintenance is essential in keeping your coffee brewer looking and working like new. To clean the coffee
brewer and components, prepare a mild solution of detergent and warm water.
CAUTION – Do not use cleansers, bleach liquids, powders or any other substance containing chlorine. These products promote corrosion and
will pit the stainless steel. USE OF THESE PRODUCTS WILL VOID THE WARRANTY.
DAILY CLEANING
1. Wipe exterior surfaces with a damp cloth, removing spills and debris.
2. Slide the brewcone out and clean it. Wipe the sprayhead area with a cloth soaked in a mild detergent solution.
3. Rinse and dry the brewcone and sprayhead area.
4. Drain drip trays of coffee.
5. Dry the tray.
WEEKLY CLEANING
1. Turn off unit at the power switch, behind the unit. Allow the brewer to cool.
2. Clean the sprayhead and dome plate area.
a. Remove the sprayhead, unscrewing counterclockwise from the dome plate.
b. Thoroughly clean and rinse the dome plate area.
c. Clean the brewcone rails with a brush soaked with a mild detergent solution. Rinse the area with a cloth soaked with clean water,
removing any residual detergent.
d. Dry the area.
c. Attach the sprayhead.
Cleaning the Thermoserver
1. Drain coffee from the server.
2. Fill the liner with a mild detergent solution and let it stand for 10 to 15 minutes.
3. After about 15 minutes take a sponge brush and scrub out the stainless steel liner.
4. When clean, drain out the soapy solution from the server.
5. Fill the server with clean water to rinse detergent from inside the unit. Repeat this rinsing until the water runs clear.
CLEANING OF THERMOSERVER FAUCET
1. Remove the faucet handle assembly. Take hold of the bonnet and turn counterclockwise to unscrew it from the faucet.
2. Clean the handle assembly with a mild detergent solution. When clean, rinse the handle with water. Inspect for cracks
or tears in the seat cup. Replace if damaged.
3. Clean the coffee level gauge glass.
a. Remove the sight glass cover by pulling up and off from the front of the server.
b. Using the narrow brush provided for this purpose, brush out the inside of the glass with a detergent solution.
Rinse the sight glass tube of all detergent residue.
c. Pay special attention to the small gauge glass liquid level hole on the body of the faucet. You can brush this
out with a small pipe cleaner.
d. Replace the sight glass. Make sure the top and bottom silicone seals are seated.
10

Advertisement

loading

This manual is also suitable for:

Thermopro singleTp2sTp2t