Limiting Values; Recommended Operating Conditions; Static Characteristics - Philips CBT3384 Product Data Sheet

10-bit bus switch with 5-bit output enables
Table of Contents

Advertisement

NXP Semiconductors

7. Limiting values

Table 4.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
T
= 40 C to +85 C, unless otherwise specified.
amb
Symbol
Parameter
V
supply voltage
CC
V
input voltage
I
I
output current
O
I
input clamping current
IK
T
storage temperature
stg
[1]
Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under
conditions for extended periods may affect device reliability.
[2]
The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.

8. Recommended operating conditions

Table 5.
Operating conditions
All unused control inputs of the device must be held at V
Symbol
Parameter
V
supply voltage
CC
V
HIGH-state input voltage
IH
V
LOW-state input voltage
IL
T
ambient temperature
amb

9. Static characteristics

Table 6.
Static characteristics
Voltages are referenced to GND (ground = 0 V).
Symbol
Parameter
V
input clamping voltage
IK
I
input leakage current
I
I
supply current
CC
I
additional supply current
CC
V
pass voltage
pass
C
input capacitance
I
C
off-state input/output
io(off)
capacitance
CBT3384_6
Product data sheet
Conditions
V
< 0 V
O
V
= 0 V
I/O
or GND to ensure proper device operation.
CC
Conditions
operating in free air
Conditions
V
= 4.5 V; I
= 18 mA
CC
I
V
= 5.5 V; V
= GND or 5.5 V
CC
I
V
= 5.5 V; I
= 0 mA;
CC
O
V
= V
or GND
I
CC
per input pin; V
= 5.5 V; one input at
CC
3.4 V, other inputs at V
CC
output HIGH; V
= V
= 5.0 V;
I
CC
I
= 100 A
O
control pins; V
= 3 V or 0 V
I
port off; V
= 3 V or 0 V; nOE = V
I
Rev. 06 — 2 November 2009
10-bit bus switch with 5-bit output enables
[1]
Min
[2]
-
Section 8.
is not implied. Exposure to absolute-maximum-rated
Min
4.5
2.0
-
40
T
amb
Min
-
-
-
[2]
-
or GND
3.6
-
-
CC
CBT3384
Max
0.5
+7.0
0.5
+7.0
128
50
-
65
+150
Typ
Max
-
5.5
-
-
-
0.8
-
+85
= 40 C to +85 C
[1]
Typ
Max
-
1.2
-
1
-
3
-
2.5
3.9
4.2
4.0
-
10.0
-
© NXP B.V. 2009. All rights reserved.
Unit
V
V
mA
mA
C
Unit
V
V
V
C
Unit
V
A
A
mA
V
pF
pF
4 of 14