MAINTENANCE

WARNING
DISCONNECT MAIN ELECTRICAL
POWER TO THE UNIT BEFORE
ATTEMPTING ANY MAINTENANCE.
FAILURE TO DO SO CAN CAUSE
ELECTRICAL SHOCK RESULTING IN
SEVERE PERSONAL INJURY OR
DEATH.

FILTERS

Filter application and placement are
critical to airflow, which may affect the
heating and cooling system perfor-
mance. Reduced airflow can shorten
the life of the systems major compo-
nents, such as motor, limits, elements,
heat exchanger, evaporator coil or com-
pressor. Consequently, we recommend
that the return air duct system have
only one filter location. The most com-
mon location will be inside the furnace
or a filter base. For systems with a
return air filter grill or multiple filter
grills, can have a filter installed at each
of the return air openings. DO NOT
DOUBLE FILTER THE RETURN AIR
DUCT SYSTEM. DO NOT FILTER THE
SUPPLY AIR DUCT SYSTEM.
If high efficiency filters or electronic air
cleaners are used in the system, it is
important that the airflow is not reduced
to maximize system performance and
life. Always verify that the systems air-
flow is not impaired by the filtering sys-
FIGURE 42
FILTER RETAINING ROD
60
TABLE 19
FILTER SIZES
UPFLOW FILTER SIZES AS SHIPPED
FURNACE
INPUT
BOTTOM
WIDTH
BTUH
SIZE
17
/
"
50, 75
15
3
/
" X 25"
1
2
4
21"
75, 100
19
/
" X 25"
1
4
24
/
"
125
22
3
/
" X 25"
1
2
4
tem that has been installed, by perform-
ing a temperature rise and temperature
drop test.
Keep the air filters clean at all times.
Vacuum dirt from filter, wash with deter-
gent and water, air dry thoroughly and
reinstall.
See Table 19 and Figures 42 through
44 for proper filter sizes and locations.
1. 21"-100,000 BTUH unit requires
removal of 3
/
" segment of filter and
1
2
frame to get proper width for a side
filter.
2. 24
1
/
"-125,000 BTUH units require
2
removal of 7" segment of filter and
frame to get proper width for a side
filter.
SIDE
QUANTITY
SIZE
15
3
/
" X 25"
1
4
*NOTE: Some filters must be
15
/
" X 25"
1
3
4
ordered or resized to fit certain
15
3
/
" X 25"
1
4
units and applications.
IMPORTANT: Do not operate the
system without filters. A portion of
the dust entrained in the air may
temporarily lodge in the air duct runs
and at the supply registers. Any cir-
culated dust particles will be heated
and charred by contact with the fur-
nace heat exchanger. This sooty
residue will soil ceilings, walls,
drapes, carpets, and other house-
hold articles. Soot damage may also
result when certain types of candles
are burned, or candlewicks are left
untrimmed.
FILTER
ROD
45-24095-01