80.0-82.2% a.f.u.e. downflow gas furnaces; models with input rates from 50,000 to 150,000 btu/hr [15 to 44 kw] (8 pages)
Summary of Contents for Rheem RGPS series
Page 1
Gas Furnaces RGPS Series Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E.† Input Rates 50-150 kBTU ENER UIDE Annual Fuel Utilization Efficiency - AFUE THIS MODEL 80.0% HIGH ✝ A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.
Table of Contents RGPS Series TABLE OF CONTENTS Standard & Optional Equipment ..............3 Model Features/Physical Data & Specifications..........4 Model Number Identification ................5 Dimensional Data ..................6-7 Blower Performance Data ................8 Accessories....................9 Limited Warranty ..................10...
(Please note: a thermostat is not All models can be converted by a qualified Rheem distributor or local included as standard equipment.) Flame sensor diagnostics. service dealer to use L.P. (propane) gas without changing burners.
Model Features/Physical Data & Specifications RGPS Series Model Features Physical Data and Specifications MODEL NUMBERS 05EAUER 07EAMER 07EAMGR 10EBRJR 10EAMER 10EBRGR 12EARJR 15EARJR RGPS- SERIES 05NAUER 07NAMER 07NAMGR 10NBRJR Input-BTU/Hr [kW] ➁ 50,000 [15] 75,000 [22] 75,000 [22] 100,000 [29]...
Model Number Identification RGPS Series Model Number Identification — Rheem P = Upflow/ Design Series Heating Input Designation Variations Blower Designation [mm] Heating & Cooling Fuel Furnace Horizontal Designation R = Natural Gas - S = 2nd A = Standard...
Dimensional Data RGPS Series Upflow Application Dimensional Data: Upflow Model REDUCED CLEARANCE (IN.) [mm] MODEL LEFT RIGHT SHIP. WGTS. RGPS- BACK FRONT VENT SIDE SIDE (LBS.) [Kg] ➀ 4 [102] ➁ 1 [25] 3 [76] 6 [152] ➂ [356] [326]...
Dimensional Data RGPS Series Horizontal Application WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR HORIZONTAL APPLICATION OR INSTALLATION ON ITS BACK, WITH ACCESS DOORS FACING UPWARDS. Dimensional Data: Horizontal Model REDUCED CLEARANCE (IN.) [mm] MODEL LEFT RIGHT SHIP. WGTS.
RXPF-F01 and F02 None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: U.S. & Canada FOSSIL FUEL KIT—is for use with Rheem Value Series Heat Pumps None required for high altitudes. and air furnaces. RXPF-F02 meets TVA requirements. 80+ HIGH ALTITUDE INSTRUCTIONS...
Limited Warranty RGPS Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts* (Registration Required) ..Ten (10) Years which fails in normal use and service within the applicable Heat Exchanger ........Twenty (20) Years period stated, in accordance with the terms of the limited warranty.
Page 12
The new degree of comfort. ™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Fort Smith, Arkansas 72917 •...