4. Application Development
Measuring Analog Output tool
This is an analog output and measurement utility able to sample indefinitely using the FIFO memory.
An event is triggered when the remaining conversion data in memory reaches a specified level and this
causes the new output data to be loaded. The utility also shows a visual representation of the data in the
FIFO memory.
The number of channels, whether to use an internal or external clock, conversion speed, number of
times to sample before generating an event, and number of samples to load at each event can be
specified. As an event is also generated if a sampling clock error occurs, you can use the utility to test
the conversion operation under a range of different conditions.
Step to use
(1) Use the combo box at the top left of the window to select the device name of the device to use, then
click the [Set] button.
(2) Specify the conversion conditions in the analog output setup window.
An event is triggered and the next block of data is loaded after the number of samples specified in
the settings has been output. Clicking the OK button saves the settings and returns to the previous
window.